Remove the two (2) 10 x 1/2" sheet metal screws holding the capillary tube clamp, if present, to the
bottom of the affected element pan.
Remove four (4) nuts attaching the wires to the elements. Mark the wires for proper replacement.
Remove five (5) 5/16 hex nut holding the element pan to the griddle plate and lower the element pan until
it clears the attaching stud.
Remove the element pan from the range and remove and discard affected element.
Clean all slag and debris from element pan. Make sure there are no sharp objects remaining at the point
where the old element shorted.
Reverse procedure for Installation.
CAUTION:
Make sure element pan is clamped tightly to the bottom of griddle plate or hot top and
that thermostat capillary tube is secure in capillary clamp and tight against bottom of griddle plate, if
present.

PREPARATION FOR RESHIPMENT

Refer to Installation Instructions. Follow these instructions in reverse order. When range is disassembled
coat the exterior and surfaces with protective oil for preservation during storage. Then crate each major
piece in a wooden box suitable for forklift access. Insure that adequate cushioning is provided on all
sides to prevent in-transit damage.