S
TOPPING THE
P
ULLER
S
HUTTING
D
OWN
P
THE
ULLER
C
OMBINATION
C
ONTROL
F
EATURES
4-28
O
1
Remove extrudate from the puller.
2
Press the red Stop button.
3
Turn rotary disconnect to OFF.
4
Rotate the 10-turn potentiometer to zero
speed.
Note: Always start puller with potentiometer
set at zero (0).
To shut down the puller, perform the stopping procedure listed
above. No additional steps are necessary if the puller is shut
down for short period of time.
If the puller is shut down for an extended period of time, belts
can acquire "set." If this occurs, let the puller run for 20-30
minutes before use. This should remove any set from the
belts.
There are four buttons below the Cutter Control and Puller
control. They are:
Cutter Power On/Off
Turn the Cutter Power On/Off to shut down the cutter por-
tion of the combination for blade replacement, etc., without
shutting down the puller portion.
E-Stop button
Press to stop the combination Puller/Cutter in an emer-
gency.
Puller Start button
Pressing this button energizes the puller portion.
Puller Stop button
Press this button to shut down the puller portion.
PERATION
CSC Combination Puller/Cutter
WARNING: Safe Stopping
Do not use any part of the guard circuit or the
rotary disconnect to stop the belt puller.
Use the recommended procedure to assure a
safe stopping.