Deleting User codes
User Code Level: Master only.
1. Access the User Menu.
2. Press the COMMAND key until USER CODES? displays.
3. Press any Select key.
The keypad displays ADD DEL CHG SEND.
4. Select DEL to delete a user code from the system.
5. At the USER NUMBER: — prompt, enter the user number you
want to delete and press COMMAND. The display changes to
USER # DELETED.
6. The display then changes back to USER NUMBER: — for you
to delete another user. Press the Back Arrow key twice to
exit the User Menu.
Sending User codes to Z-Wave locks
User Code Level: Master only.
Your system may be pre-programmed at installation to support
Z-Wave door locks. This option allows you to send user codes of
user numbers 2-20 (Master and Standard) to all compatible Z-Wave
locks. Once codes have been received by the lock, a valid user
code entered at the lock (by user number 2-20) will lock the door
or unlock and disarm the system according to the user's privileges.
1. Access the User Menu.
2. Press the COMMAND key until USER CODES? displays.
3. Press any Select key. The keypad displays ADD DEL CHG SEND.
4. Select SEND to send user codes of user numbers 2-20 (Master
and Standard) to all compatible Z-Wave locks on your system.
Note: The process of sending the user codes to the locks may
take several minutes.
5. If all locks receive the user codes, the display will return to
the Status List.
6. If a lock does not receive the user codes, the keypad displays
CODES NOT SENT TO ALL LOCKS.
User Menu

Schedules

User Code Level: Master only.
Function: The Schedules function allows you to program the times
at which you normally turn your burglary protection on and off
each day of the week. This information can then be used by the
system to automatically arm or disarm the burglary protection.
You can also use the Closing Check/Extend feature with Schedules
to ensure your system is armed by an authorized user at a specific
time. This option sounds the keypad buzzer and displays CLOSING
TIME! when a schedule expires. Users still on the premises are
required to arm the system or extend the schedule. If the system
is not armed, or the schedule not extended, a report can be sent
to the central station and/or a cell phone.
When a schedule expires and CLOSING TIME! displays, the keypad
next displays ENTER CODE: -. To silence the keypad buzzer and
extend the schedule for one hour, a user must either enter a valid
user code or present a card to the card reader.
Also, when a closing schedule expires, your system may turn on
the Late to Close Output. This output turns off anytime your
system is armed, or a schedule is extended or changed. See
System Setup for Output information.
Your system provides you with three different types of schedules:
Permanent schedules are used for automatic arming and
disarming and always occur at the same time until you change or
delete them.
Extend schedules allow an authorized user to extend the present
day's permanent scheduled closing time.