Summary of Contents for Wincor Nixdorf Beetle S-II plus
Page 1
BEETLE /S-II plus (H1- Mot her bo ard) Modular POS System User Manual...
Page 2
Please send us a copy of this page if you have any constructive criticism. We would like to thank you in advance for your comments. With kind regards, Your opinion: Wincor Nixdorf International GmbH Documentation RD PD15 Rohrdamm 7 D-13629 Berlin E-Mail: retail.documentation@wincor-nixdorf.com...
Page 3
BEETLE /S-II plus (H1 Motherboard) Modular POS System User Manual, Edition July 2009...
Contents Ma nu fac tu rer´s Cer ti fi ca ti on..........1 Tes ted Sa fe ty....................1 FCC-Class A De cla ra ti on................1 Im por tant no tes ...................2 In tro duc ti on................4 About this ma nu al ..................4 Care of the BEET LE /S-II plus ..............5 Re cy cling the BEET LE /S-II plus ..............5 War ran ty .....................7...
Page 6
Sys tem Unit................21 Jack Plug 3.5 mm (MIC, SPK) ..............22 Mini-DIN (KYBD)..................22 D- Sub Plug (COM1).................22 D- Sub- Jack po wer supp lied (COM2*) .............23 USB (Uni ver sal Se ri al Bus)- A, USB 2.0 ...........23 RJ45 (LAN) ....................23 CRT ......................24 PLINK TFT (TFT- VGA Mo ni tor) ...............24 Dis con nec ting ca bles............25...
Manufacturer´s Certification The de vi ce com plies with the re qui re ments of the EEC di rec ti ve 2004/108/EC with re gard to ‘Electromagnetic com pa ti bi li ty" and 2006/95/EG “Low Vol ta ge Directive”. Therefore, you will find the CE mark on the device or packaging.
Customer Service of Wincor Nixdorf or your dealer must be notified. The li thi um bat te ry must be dis po sed of in ac cor dan ce with lo cal re gu la tions for spe ci al was te.
Page 9
The de vi ce may only be re pai red by aut ho ri zed qua li fied per son nel. Un aut ho ri zed ope ning of the de vi ce and in ex pert ly car ried-out re pairs may not only se ri ous ly jeo par di ze the sa fe ty of the user, but also can cel all war ran ty and liability agreements.
Whatever configuration you need: Wincor Nixdorf International GmbH offers the right solution. So, whenever you want to expand your BEETLE /S-II plus, please contact your Wincor Nixdorf International GmbH branch office or your dealer. About this manual This documentation is intended to help you to work with the POS system and to serve as a reference work.
Also switch your equipment off when you take a longer break or finish your work. At this time, there are still some parts that are not reusable. Wincor Nixdorf International GmbH guarantees the environmentally safe disposal of these parts in a Recycling Center, which is certified pursuant to ISO 9001 and ISO 14001.
Page 12
Plea se con tact your com pe tent branch or the Re cy cling Cen ter Pa der born (for Eu ro pe an coun tries) for in for ma ti on on how to re turn and re-use de vi ces and dis po sa ble ma ter ials un der the following mail address.
Warranty Win cor Nix dorf gua ran tees ge ne ral ly a war ran ty en ga ge ment for 12 months be gin ning with the date of de li very. This war ran ty en ga ge ment co vers all da ma ges which oc cur de spi te a nor mal use of the pro duct.
BEETLE /S-II plus- the modular POS System Overview You can connect a variety of peripherals to your modular POS system BEETLE /S-II plus and thus implement a wide range of expansion stages. You can connect a four-line alphanumeric customer display and a four line cashier display.
Should you notice any transport damages or discrepancies between package contents and delivery ticket or functional defects please inform your contracting parties or the branch office of Wincor Nixdorf immediately. Please indicate the number of your delivery ticket and delivery ticket position and serial numbers of the respective devices.
Ho ri zon tal in stal la ti on Mind the minimum distances indicated below! If the equipment is to be fitted, you also must ensure that the specified minimum distances are maintained and constant ventilation is provided. The immediate ambient temperature of the system must not exceed 40°...
Ver ti cal in stal la ti on of the equip ment The minimum top and bottom distances listed in the figure must be maintained; otherwise, a sufficient ventilation of the equipment is not guaranteed. 60 mm 50 mm 100 mm The minimum distances listed in the figure must be maintained;...
Page 18
A surface made of nonflammable material (e.g. concrete or metal) must be located underneath the vertically mounted power supply unit. BEETLE /S-II plus...
Cab ling of the BEETLE /S-II plus Follow the steps below in the order given when installing devices: The cable cover must be removed, if present. Plug one end of the power cable into the socket of the BEETLE /S-II plus. Plug in and secure the data cable.
Ex works, the BEETLE /S-II plus is configured to your order. Your configuration must be subsequently adapted to support supplementary devices such as scanners. For more information, contact the Wincor Nixdorf International GmbH branch office responsible for your area. BEETLE /S-II plus...
ON But ton With a power supplied power unit (power switch switched to 1) you switch on the system with the power ON button on the front side of the system unit. Light-emit ting Di ode (LED) The LEDs are labelled with HDD for the right LED and with POWER for the left LED.
Power Supply The power supply can be connected to all conventional power supply networks. It automatically adjusts itself to the particular voltage and is fan-cooled. The power output of the power pack is maximum 304 W. The Po wer Supp ly Unit (PSU) car ries the 80plus cer ti fi ca te. This me ans that the PSU will re ach an ef fi cien cy of at least 80% with each a load of 20%, 50% or 100%.
At the front side of the box you will find the ON button which will turn on the system. The system is automatically switched off, when the operating system is shut down. Pushing (approx. 5 seconds) the ON button at any time will shut down the system.
RJ12 (CASHDR, Geld la de) The power supply unit has one RJ12 socket for connecting a cash drawer. Make sure that the connector is plugged firmly into the socket to prevent malfunctioning. RJ12 plugs lock in when you insert them. Power is supplied to the cash drawer via this socket, P24V +5% / -15%.
System Unit Al ways make sure that the sys tem is swit ched off when you do cab ling works. Connecting peripherals with the system switched on is not allowed (exception: USB devices). PLINK TFT COM3* COM4* KYBD COM2* COM1 Jack plug, 3.5 mm, MIC Mini DIN (KYBD) D- Sub (COM1)
Make sure that the connector is plugged securely into the socket to prevent possible malfunctioning. If scales which are not supplied by Wincor Nixdorf International GmbH are connected to the BEETLE /M-II plus, you must obtain a Wincor Nixdorf licence for the driver software.
D- Sub- Jack po wer supp lied (COM2*) The interface connection is a 9-pin D-sub jack for scanner, user or customer displays without own power supply. Make sure that the con nec tor for the cus to mer dis play is scre wed firm ly to the so cket to pre vent pos si ble mal functio ning.
You can connect a monitor to the BEETLE /M-II plus via the 15-pin D-sub jack on the CRT adapter. Power is supplied to the monitor via the AC-outlet on the BEETLE /M-II plus, located on the back of the housing. A LCD screen can be connected alternatively if a TFT adapter is installed.
Dis con nec ting ca bles Never unplug a cable by pulling on the cable; always take direct hold of the plug itself. Follow the procedure below when disconnecting cables: Turn off all power and equipment switches. Unplug all data communication cables from the sockets of the data networks.
Page 32
To release TFT (LCD) connectors, press the interlocks on the left and right side. Der Hosiden-Ste cker (Drucker- anschluss) ist mit ei ner Ver rie ge lung ge gen un be ab sich tig tes Lö sen der Ver bin dung ver se hen. Um die sen Ste cker zu lö...
Storage Media Following storage media are available one or two 2.5" SATA- hard disk or one or two 2.5" solid state disk drive. A solid state disk drive is a data storage drive that uses memory elements in place of a rotating disk to store data. The SSD easily subsitutes the hard disk and emulates a hard disk drive interface.
Page 34
Push the metal plate (1). Tilt the hard disk hol der in direction of arrow (2). Lift up the dri ve and remove it. Loosen the connecting cables. Ca ble of po wer supply Data ca ble BEETLE /S-II plus...
Page 35
Take the holder out. Loo sen the four Phillips head screws (see arrows) at the holder with a screwdriver. En su re that you hand le the hard disk with ex tre me cau ti on du ring the in stal la ti on. Never touch bare electronics. Change the hard disk.
Page 36
C on nect both ca bles to the hard disk. Insert the drive holder. Make sure that the buffers are corresponding to the stampings in the base plate (see arrows). Carefully tilt the hard disk carrier into the orginally position. Make sure that the drive holder will not pinsh cables.
USB- Controller (optional) There are three 12V and one 24V USB interfaces on an optional available board. Further USB interfaces (3 x 12V PoweredUSB) are available instead of the COM3*/COM4*- submodule. You can connect or disconnect USB devices during operation of your BEETLE, provided that these devices comply with the specifications according to usb.org.
COM5*- COM8*- Interfaces (optional) The standard system is configured with three further COM* interfaces. In addition you can install an optional PCI board with maximal four COM* interfaces (COM5*, COM6*, COM7*, COM8*). Scanners, customer and operator displays without own power supply are connected to these serial interfaces.
CRT- or TFT Adap ter (optional) Both adapters may be installed in parallel. You can connect a CRT monitor or/and a TFT-LCD module with optional touch screen functionality. When installing a TFT- adapter with touchscreen functionality the cable for the internal loudspeaker must be removed to activate the loudspeaker in the screen display.
Starting up the system The configuration label shows you the equipment included in your modular BEETLE /M-II plus system. The label is located at the underside of the BEETLE /M-II plus. The data specified there are required for entering the setup parameters (see section BIOS Setup in the manual “BEETLE POS Motherboard, F2-CPU”).
Page 41
The logical drives are designated C: and D:. The network is always assigned to the C: drive during the runup procedure. The hard disk can be assigned to the C: or D: drive. The system can only be started from the hard disk if the disk has been configured as the C: drive. Corresponding to the Setup configuration the modular BEETLE /iClick system can be booted from the following drives: Hard disk in drive C:...
Appendix Technical Data BEETLE /S-II plus Dimensions Width 310 mm Depth 280 mm (w/o cable cover) 352 mm (with cable cover) Height 103 mm Weightt approx. 6.5 kg Climatic category Class 3K3 DIN IEC 721-3-3 Class 2K2 DIN IEC 721-3-2 Class 1K2 DIN IEC 721-3-1 Temperature:...
Interfaces COM1 (w/o power supply), COM2* (with power supply) Optional: COM5*- COM8* (with power supply) via PCI- COM- board 2 Standard USB + 2 Standard USB at the front side Optional: 3 PoweredUSB 12V and 1 PoweredUSB 24V via a Hub controller 3 PoweredUSB instead of COM3*/COM4* optional onboard supports on board adapter for VGA-, CRT screens...
Extensions Rear Pa nel (CRT/VGA, DVI) DC 24V CASHDR ONLY COM3* COM4* KYBD COM2* COM1 Rear Pa nel (CRT/VGA, PLink*, USB and USB or COM) PLINK TFT DC 24V CASHDR ONLY KYBD COM1 COM2* Rear Pa nel (CRT/VGA, PLink*, USB, COM) COM5* COM6* PLINK TFT...
To tal Cur rent Con sump ti on of In ter fa ces The total current consumption at 5V interfaces must not exceed 5A. each COM* = 300mA, in total 500mA each USB = 500mA, in total 2A each USB (HUB) = 500mA, in total 2A TFT/LCD-Display Max.
Glossary A bit is a binary digit (0 or 1). It is the smallest unit used in data processing. Controller Serves to control data input and output in a data processing system or between a computer and the connected peripherals. Abbreviation of central processing unit.
Page 48
Express - the transfer rates are increased by switched point-to-point connections. A switch connects two PCIe components at a time with full bandwidth and speed. PCMCIA Abbreviation for Personal Computer Memory Card International Association. Industry standard for memory cards. Plug and PLay (PnP) PnP means the automatic recognition of hardware components by the system.
Abbreviations European Symbol of Conformity RS 232 Schnittstelle Central Processor Unit (for example INTEL Celeron-M) Cathode Ray Tube Canadian Registration (Recognized by UL) DIMM Dual Inline Memory Module Deutsches Institut für Normen (German Institute for Standards) D-Sub D- Shaped Subminiature DVD-ROM Digital Versatile Disc Random Access Memory DVD-RW...
Page 50
Verband der Elektrotechnik, Elektronik und Informationstechnik e.V. German Association for Electrical, Electronic and Information Technologies Wide Area Network W LAN Wireless Local Area Network Wincor Nixdorf International GmbH Zero Cache BEETLE /S-II plus...
Page 51
Herausgegeben von/Published by Wincor Nixdorf International GmbH D-33094 Paderborn 01750177766A Bestell-Nr./Order No.:...