General Information; Xtd 1.9 Insert Specifications - Flame Energy XTD 1.9 Installation And Operation Manual

Hide thumbs Also See for XTD 1.9:
Table of Contents

Advertisement

XTD 1.9 Insert Installation and Operation Manual
2

General Information

2.1 XTD 1.9 Insert Specifications

Fuel Type
Test Standards (safety)
Test Standard (emissions)
Heating capacity range*
Maximum heat output**
(EPA test fuel)
Maximum heat output**
(natural hardwood fuel)
Optimum efficiency
Test Standard (efficiency)
Approximate Burn Time
Shipping Weight
Firebox Volume
Maximum Log Length
Flue Outlet Diameter
Baffle Material
* Burn time and heating capacity may vary subject to location in home, chimney draft,
chimney diameter, locality, heat loss factors, climate, fuels and other variables.
** The EPA test fuel is dimensional Douglas fir pieces stapled together into cribs with air
spaces between. We also test using the same procedure except using split hardwood
firewood to reflect real-world heat output. This insert is not intended to operate at its peak
heat output continuously.
*** East-west: through the door you see the sides of the logs; north-south: through the door
you see the ends of the logs.
8
Cordwood
ULC S628, UL 737 and UL 1482
EPA Method 28 (40 CFR Part 60)
500 to 2100 sq. ft. (47 to 195 m
32 200 BTU/h (9,4 kW/h).
75 000 BTU/h (22 kW/h).
77,2 %
CSA B415.1
6 to 8 hours
398 lb (181 kg)
3
2,1 cu.ft. (0,060 m
)
20" east-west***
6" (150 mm) diameter (vertical)
Vermiculite
2
)