Pipe Assembly; Pipe-To-Crossmember Clearance - Subaru 2001 FORESTER Service Manual

Hide thumbs Also See for 2001 FORESTER:
Table of Contents

Advertisement

RHD model
(1)
Clearance between blow-by hose and pipe: 3 — 5 mm (0.12 — 0.20 in)
(2)
No interference is allowed between hoses
(3)
Clearance between side frame and hose: 15 mm (0.59 in) or more
(4)
Clearance between crossmember and pipe: 5 — 13 mm (0.20 — 0.51 in)
(5)
Steering gearbox
11) Finally check clearance between pipes and/or
hoses, as shown above.
If clearance between cruise control pump and
power steering hose is less than 10 mm (0.39 in),
proceed as follows:
(1) Move clamped section (A) (refer to figure
above.) down to a point where pipe is close to
crossmember.

Pipe-to-crossmember clearance:

10 mm (0.39 in), min.
(2) Check that clearance between cruise con-
trol pump and power steering hose is at least 10
mm (0.39 in). If it is not, bend section (B) down
until a clearance of at least 10 mm (0.39 in) is
obtained.

PIPE ASSEMBLY

PS-89
Power Assisted System (Power Steering)
B4M1205B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents