Thin Facing Installation - Travis Industries 864 See Through Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for 864 See Through:
Table of Contents

Advertisement

32
Thin Facing Installation (tile, marble, or other non-combustible under 1" (25mm) thick)
Upgrade faces are available for this fireplace and may influence facing installation. Consult with your
Travis Dealer if you are using an upgrade face.
Do not install tile (or other material)
in front of the glass frame,
convection channel, or access panel
openings. This area must remain
open to access internal components
and for convection air.
TOP VIEW
Fireplace
Tile
NOTE FOR FPX FACES:
FPX arched faces require the FPX Face
Upgrade Kit (sku 98500686) and a
triangular piece of facing in these upper
corners. See the instructions included
with the face for further details.
2-7/8"
(73mm)
© Travis Industries
Installation
(for qualified installers only)
Facing is installed to this
edge of the fireplace.
Framing
Nailing Bracket
Drywall
7-7/8" (200mm)
Raised Fireplaces:
Facing is installed 1" (25mm)
maximum above the base of the
fireplace.
FRONT VIEW
37"
940mm
4090507
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1" (25mm) maximum above the
base of the fireplace. The fireplace may be raised to
accommodate thicker hearth materials.
1-1/8"
29mm
34-1/4"
870mm
1" (25mm)
2" (51mm)
100-01217_000

Advertisement

Table of Contents
loading

This manual is also suitable for:

864 st gs