4.7.2 Universal Offset Support
This support is used to support the chimney above an offset. When the chimney offset is used to pass
through a wall, this support may be used on the wall to support the chimney. For offset support installation,
refer to the instructions provided with the support by the chimney manufacturer. Many manufacturers will
provide the maximum height of chimney that can be supported by the support. Make sure you respect
those parameters.
4.8 Installation Instructions for Masonry Application
WARNING:
BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A
QUALIFIED CHIMNEY SWEEPER.
The following requirements must be respected:
1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing
bricks that could inhibit correct installation of the liner.
2. The clearance to combustible material must be a minimum of 1" between the outside of the masonry
and any wood framing or loose insulation.
3. The chimney must be built in accordance with the current building code.
4. No other appliance can be connected to the same chimney.
Installation:
The chimney must be relined with a stainless steel liner of the same diameter as the outlet of the
fireplace. For connection at 30
insulated chimney. Verify availability and installation instructions for this connector with the chimney
manufacturer.
40
o
o
or 45
angle, a special connector must be used to connect the liner to the
ME300 ‐ Installation and Operation Manual