4.7.2 Universal Offset Support 
This  support  is  used  to  support  the  chimney  above  an  offset.  When  the  chimney  offset  is  used  to  pass 
through a wall, this support may be used on the wall to support the chimney. For offset support installation, 
refer to the instructions provided with the support by the chimney manufacturer.  Many manufacturers will 
provide  the  maximum  height  of  chimney  that  can  be  supported  by  the  support.  Make  sure  you  respect 
 
those parameters.
4.8 Installation Instructions for Masonry Application 
WARNING: 
BEFORE STARTING THE INSTALLATION, THE MASONRY CHIMNEY MUST BE INSPECTED BY A 
QUALIFIED CHIMNEY SWEEPER. 
The following requirements must be respected: 
1. The chimney must be absolutely clear of any soot residue or creosote. Check for cracks, loose or missing 
bricks that could inhibit correct installation of the liner. 
2. The clearance to combustible material must be a minimum of 1" between the outside of the masonry 
and any wood framing or loose insulation. 
3. The chimney must be built in accordance with the current building code. 
4. No other appliance can be connected to the same chimney. 
Installation: 
The  chimney  must  be  relined  with  a  stainless  steel  liner  of  the  same  diameter  as  the  outlet  of  the 
fireplace. For connection at 30
insulated  chimney.  Verify  availability  and  installation  instructions  for  this  connector  with  the  chimney 
manufacturer.  
40 
o
o
 or 45
 angle, a special connector must be used to connect the liner to the 
ME300 ‐ Installation and Operation Manual 