3.9 Fresh Air Intake Kit 
During  operation,  the  fireplace  requires  fresh  air  for  combustion  and  draws  air  out  of  the  house.  It  may 
starve other fuel burning appliances such as gas or oil furnaces. As well, exhaust fans may compete for air, 
causing  negative  pressure  in  the  house,  resulting  in  smoke  entering  the  house  from  the  fireplace.  This 
situation is aggravated in modern airtight houses. To overcome this problem, we strongly recommend that 
you bring fresh air to the fireplace. Check with local authorities having jurisdiction in your area, it may be 
mandatory. 
THE INSULATED FLEXIBLE PIPE LENGTH SHOULD BE SUFFICIENT AND HAVE A CONFIGURATION TO AVOID 
CONDENSATION.   
THE OUTSIDE WALL TERMINATION MUST NOT BE INSTALLED AT MORE THAN 50% OF THE TOTAL HIGHT 
OF THE CHIMNEY AND AT THE MOST 10 FT. (3 M) ABOVE THE BASE OF THE FIREPLACE. 
THE FRESH AIR MUST COME FROM OUTSIDE THE HOUSE. THE AIR INTAKE MUST NOT DRAW AIR FROM 
THE ATTIC, FROM THE BASEMENT, OR FROM A GARAGE. 
THE  OUTSIDE  WALL  TERMINATION  SHOULD  BE  INSTALLED  WHERE  IT  IS  NOT  LIKELY  TO  BE  BLOCKED  BY 
SNOW OR EXPOSED TO EXTREME WIND AND AWAY FROM AUTOMOBILE EXHAUST FUMES, GAS METER 
AND OTHER VENTS. 
Your fresh air kit contains the following components:  
a. One (1) 4" adapter (D); 
b. Two (2) screws (E);  
The following components are not included: 
a. A 4" insulated flexible pipe (This HVAC type pipe must comply to ULC S110 and/or UL 181, Class 0 or 
Class 1 Standards and must withstand temperatures up to 250 °F. 
b. The outside air inlet cap  
c. The 2 adjustable clamping ring 
To complete the fresh air installation, you will need a 4" insulated flexible pipe.  Use the length required for 
your  installation  while  respecting  the  maximum  length  of  30  ft  (9  m).  To  avoid  condensation,  it  is 
recommended to use an insulated pipe long enough and containing a "P‐Trap" loop. This configuration can 
be found inside the chase, but must at all times maintain clearances to combustibles. 
Remove  the  knock  out  (A)  located  on  the  left‐hand  side  of  your  fireplace.  Then  cut  and  remove  the 
insulation (B) and remove the inner knock‐out (C). Install 4" adapter (D) included in your fireplace with the 2 
screws (E). 
 