3 INSTALLATION 
3.1 Fireplace Installation 
CAUTION: 
BEFORE  CLOSING  THE  WALLS,  MAKE  SURE  THAT  THE  AIR  CONTROL  MECHANISM,  THE 
FLUE DAMPER AND DOORS MECHANISM WORK PROPERLY.  
3.1.1 Installation of a Gas Log Set 
You  can  install  a  decorative  gas  appliance  or  a  vented  gas  log  set  in  the  hearth.  To  do  this,  install  an 
automatic shut‐off valve. Comply with the Standard for Decorative Gas Appliances for Installation in Vented 
Fireplaces, ANSI Z21.60 (1991) or American Gas Association draft requirements for Gas‐Fired Log Lighters 
for Wood Burning Fireplaces, Draft No. 4 dated August, 1993. 
WARNING: 
THIS  FIREPLACE  HAS  NOT  BEEN  TESTED  WITH  AN  UNVENTED  GAS  LOG  SET.  TO  REDUCE 
RISK  OF  FIRE  OR  INJURY,  DO  NOT  INSTALL  AN  UNVENTED  GAS  LOG  SET  INTO  THIS 
FIREPLACE. 
3.2 Locating the ME300 Wood Fireplace 
A. The best location to install your fireplace is determined by considering the location of windows, doors, 
and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the 
hearth extension and the mantel, and taking into consideration the location of the outside air kit and 
chimney.  If  possible,  you  should  choose  a  location  where  the  chimney  will  pass  through  the  house 
without  cutting  floor  or  roof  rafters.  Also  choose  a  location  that  allows  installing  the  least  amount  of 
offsets in the chimney. 
B. Usually,  no  additional  floor  support  is  needed  for  the  fireplace.  The  adequacy  of  the  floor  can  be 
checked  by  first  estimating  the  weight  of  the  fireplace  system.  Weights  are  given  in  the  Section 2.1: 
ME300  Wood  Fireplace  Specifications.  Next,  measure  the  area  occupied  by  the  fireplace  which  is 
normally 41 1/8" x 25 5/8" (105 cm x 65 cm). Note the floor construction and consult your local building 
code to determine if additional support is needed. 
WARNING: 
THE FIREPLACE MUST BE INSTALLED ON A LEVEL AND STRAIGHT (NOT UNEVEN) SURFACE.  
3.3 Raised base installation  
The ME300 fireplace may be installed directly on the floor or on a raised combustible or non combustible 
base. However, the upper and lower angle, for the full width of the floor protection, must be protected 2" 
horizontally  and  vertically  (E)  by  a  non‐combustible  material.  For  example,  a  sheet  metal  (not  included). 
Apart from these two corners, the sheet metal does not have to cover the rest of the wall between the base 
of the fireplace and the floor. 
Note that the non‐combustible hearth extension floor area must extend at least 16" (41 cm) in front of the 
hearth as shown in Section 3.5: Minimum Heart Extension Requirements. 
 
 
ME300 ‐ Installation and Operation Manual
 
 
11 