4.5 Offset Chimney Installation 
TABLE 2 – THE MINIMUM SYSTEM HEIGHT WHEN USING ELBOWS 
Fireplace model 
Chimney model 
Vertical installation 
Two (2) elbows 
Four (4) elbows 
After reaching the location requiring the elbow, proceed as follows: 
1. To insure a good draft, it is recommended, but non‐mandatory, to have a length of 18 inches (457 mm) 
from the top of the unit to the first offset. Install the first elbow; turn it in the required direction. Secure 
it  to  the  chimney  according  to  the  chimney  manufacturer's  instructions.    In  many  cases,  it  is 
recommended to secure connections with three (3) ½" (12 mm) metal screws. 
2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together 
according to the chimney manufacturer's instructions.  In many cases, it is recommended to use three 
(3)  ½"  (12  mm)  metal  screws.  If  the  offset  length  is  made  of  two  (2)  chimney  lengths  or  more,  many 
chimney  manufacturers  may  require  that  you  use  an  offset  or  roof  support  halfway  up  the  offset.  If 
penetrating  a  wall,  install  a  wall  radiation  shield  supplied  by  the  chimney  manufacturer  (see  Section 
4.4.1: Examples of Typical Chimney Installation). 
3. Use another elbow to turn the chimney vertically. Secure the elbow. 
4. Use a plumb bob to line up the centre of the hole. Cut a hole for the chimney in the ceiling/floor. Frame 
this hole as described previously. 
5. From below, install a firestop supplied by the chimney manufacturer. 
6. A support must be used on the first 15' section (4.6 m). 
7. Continue with the regular installation. 
4.6 Angled Wall Radiation Shield 
When passing through a combustible wall with the chimney at a 30 or 45 angle (30 or 45 in Canada and 
30 only in the USA), an angled firestop or wall radiation shield provided by the chimney manufacturer must 
be installed. Only one is required. Follow the chimney manufacturer's installation instructions. 
In  cold  climate  locations,  it  is  recommended  that  you  use  the  insulated  wall  radiation  shield  since  it  will 
maintain the home's thermal barrier. 
38 
ME300 WOOD FIREPLACE 
All models listed in Table 1 
15 ft. (4.5 m) 
15 ft. (4.5 m) 
17 ft. (5.2 m) 
ME300 ‐ Installation and Operation Manual 