3.6 Framing, Facing, Mantel, and Combustible Shelf 
3.6.1 Framing 
The  construction  of  the  framing,  facing,  and  mantel  must  be  in  accordance  with  the  standards  and  the 
following illustrations: 
A. Frame the fireplace using 2" × 3" (5 cm x 8 cm) or heavier lumber. 
WARNING:  COMBUSTIBLE  FRAMING  MATERIAL  CANNOT  BE  USED  IN  THE  SPACE  DIRECTLY  ABOVE  THE 
FIREPLACE,  EXCEPT  FOR  THE  STUDS  ABOVE  THE  FACING  THAT  SUPPORT  THE  FACING 
MATERIAL  AND  MANTEL.  THIS  AREA  MUST  REMAIN  EMPTY  FOR  A  HEIGHT  OF  6'  (1.83  M) 
MEASURED FROM THE BASE OF THE APPLIANCE. 
B. Frame  the  fireplace  with  vertical  studs  on  each  side  of  the  fireplace  running  from  floor  to  ceiling. 
Position the studs back from the front edge of the fireplace, leaving a space the thickness of the facing 
material so that the facing can be installed flush with the fireplace facing within limitations of figures 
and tables bellow. Frame headers between the vertical studs only as follows: 
 Place 2" x 3" (5 cm x 8 cm) or 2" x 4" (5 cm x 10 cm headers, only along the upper part of the front, 
side  and  back  faces.  Do  not  put  wood  or  any  combustible  material  within  the  area  above  the 
fireplace except on the front facing. 
 Place headers only as required to support the facing and mantel. 
WARNING:  DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL.  
WARNING:  THE  FIREPLACE  MUST  NOT  BE  IN  CONTACT  WITH  ANY  INSULATION  OR  LOOSE  FILLING 
MATERIAL. COVER THE INSULATION WITH DRYWALL PANELS AROUND THE FIREPLACE.  
 
ME300 ‐ Installation and Operation Manual
 
19 