Minimum Heart Extension Requirements - Ventus ME300 Installation And Operation Manual

Table of Contents

Advertisement

 
MATERIAL 
®
Micore
 160 
®
Micore
 300 
®
Durock
 
®
Hardibacker
 
®
Hardibacker
 500 
®
Wonderboard
 
Cement mortar 
Common brick 
Face brick 
Marble 
Ceramic tile 
Concrete 
Mineral wool insulation 
Limestone 
Ceramic board (Fibremax) 
Horizontal still air** (1/8") 
* Information as reported by manufacturers and other resources 
** For a 1/8" thickness. You cannot «stack» horizontal still air to accumulate R‐values; you must separate 
each layer of horizontal still air with another non‐combustible material. 
3.5 Minimum Heart Extension Requirements 
The hearth extension floor area must extend at least 16" (41 cm) in front of the hearth (A) and at least 8" 
(20  cm)  on  each  side  of  the  door  opening  (D).  The  joint  between  the  hearth  extension  and  the  fireplace 
hearth needs to be made of non‐combustible material such as sheet metal (not included). 
 
ME300 ‐ Installation and Operation Manual
Thermal Characteristics of Common Floor Protection Materials* 
 
CONDUCTIVITY (k) 
PER INCH 
0.39 
0.49 
1.92 
1.95 
2.3 
3.23 
5.00 
5.00 
9.00 
14.3 – 20.00 
12.5 
1.050 
0.320 
6.5 
0.450 
0.135 
RESISTANCE  (R) PER INCH 
THICKNESS 
2.54 
2.06 
0.52 
0.51 
0.44 
0.31 
0.2 
0.2 
0.11 
0.07 – 0.05 
0.008 
0.950 
3.120 
0.153 
2.2 
0,920** 
17 