Fan
2 State: Normal
Fan
3 State: Normal
Fan
4 State: Normal
Table 7 Command output
Field
Fan
1
State
Displaying the operating state of a power supply
Use the display power command to display the operating state of a power supply.
<HP>display power
Power
1 State: Normal
Power
2 State: Absent
Table 8 Command output
Field
Power
1, 2
State
Configuring the exception handling method
Configuration procedure
You can configure the device to handle system exceptions (such as system instruction faults, invalid
addresses, data overflow, null pointers, and division by zero operations) by using one of the following
methods:
•
Reboot—The device automatically reboots to recover from the error condition.
Maintain—The device stays in the error condition so you can collect complete data for diagnosis,
•
including error messages. You must manually reboot the device.
To configure the exception handling method:
Step
1.
Enter system view.
Description
Number of the fan.
Fan state:
•
Normal—The fan is operating correctly.
•
Absent—The fan is not in position.
•
Fault—The fan has failed.
Description
Number of the power supply.
Power supply state:
•
Normal—The power supply is operating correctly.
•
Absent—The power supply is not in position.
•
Fault—The power supply has failed.
Command
system-view
36
Remarks
N/A