Displaying The Operating State Of A Power Supply; Configuring The Exception Handling Method; Configuration Procedure - HP 870 Installation Manual

Unified wired-wlan appliance
Table of Contents

Advertisement

Fan
2 State: Normal
Fan
3 State: Normal
Fan
4 State: Normal
Table 7 Command output
Field
Fan
1
State

Displaying the operating state of a power supply

Use the display power command to display the operating state of a power supply.
<HP>display power
Power
1 State: Normal
Power
2 State: Absent
Table 8 Command output
Field
Power
1, 2
State

Configuring the exception handling method

Configuration procedure

You can configure the device to handle system exceptions (such as system instruction faults, invalid
addresses, data overflow, null pointers, and division by zero operations) by using one of the following
methods:
Reboot—The device automatically reboots to recover from the error condition.
Maintain—The device stays in the error condition so you can collect complete data for diagnosis,
including error messages. You must manually reboot the device.
To configure the exception handling method:
Step
1.
Enter system view.
Description
Number of the fan.
Fan state:
Normal—The fan is operating correctly.
Absent—The fan is not in position.
Fault—The fan has failed.
Description
Number of the power supply.
Power supply state:
Normal—The power supply is operating correctly.
Absent—The power supply is not in position.
Fault—The power supply has failed.
Command
system-view
36
Remarks
N/A