To maintain the high performance and quality finish of your Valor fire, please follow
these guidelines:
• Before attempting to clean the fire, please
remember to turn off the fire and wait for
the appliance to cool. The fire will retain
heat for some time before cleaning can
begin.
• If any pieces of debris are found in the fire
box, have the chimney inspected before
further use.
Metal Parts
• Clean the metal parts with a slightly damp
cloth and then dry.
• Do not use abrasive cleaners as these will
scratch the fire surface.
Window Glass
• Remove any stains on the window with a
non-abrasive cleaner such as a ceramic hob
cleaner. Do not use abrasive cleaners.
• The fire has been designed to so that you
can remove the window without having to
call in a service engineer. This allows you
to clean the inside of the window.
To remove the window:
1. Unscrew and remove the two knurled
screws which are under the outer case
canopy. See figure 4.
2. Pull the top of the window surround
forward. See figure 4.
3. Lift the window surround up to clear the
slots in the case apron. See figure 4. Put
the surround in a safe place.
4. Remove the window unit by turning the screws each side of the window frame ¼
turn anticlockwise. A screwdriver is provided with your fire for turning the screws.
Lift the window unit clear. See figure 5.
5. After cleaning, replace and secure the window unit to the firebox by turning the two
1
screws
/
turn clockwise with the screwdriver. Replace the surround. Make sure that
4
the outside edges of the window surround sides are inside the outer case.
OWNER'S GUIDE