A10 Inverter module
WARNING
A10 models are supplied with spare fuses housed in the controller card cover.
Be careful to replace A10 fuses with those of the correct rating (see diagram below).
The small green light (LED) on the controller marked - "POWER" - indicates if the
card is active. Each power supply has a red light (LED) to indicate mains supply.
FUSE (1) 5A FAST BLOW
FUSE (2) 50mA SLOW BLOW
FUSE (3) 3A FAST BLOW
TIMER CONTROLLED
SWITCH FOR
COURTESY LIGHT
The 310V DC supply is hazardous and potentially lethal.
The A10 inverter module should be installed and
maintained by a qualified installer.
MAINS IN
{
{
L
N
E
POWER ON INDICATOR
Page 22