Rotary Switch Setting: Info; Exit Button: Sonderfunktion - Daikin EHSX04P30A Operating Instructions Manual

Indoor unit for air-water-heat pumps daikin altherma integrated solar unit
Table of Contents

Advertisement

6
x
Parameter settings

6.10 Rotary switch setting: Info

Parameter
Overview
Display of different current operating data (see section 3.4.1).
Water Pressure
The current water pressure is displayed in bar.
T-HS
The current temperature (TVBH) of the heat generator is displayed in °C.
T-HS Setpoint
The current Inflow target temperature of the heat generator is displayed in °C (see
section 3.6.4).
T-Outside
The current external temperature is displayed °C.
T-DHW
The current temperature of the hot water storage tank is displayed in °C. If there is no hot water
function activated, "- - -" is displayed.
T-DHW Setpoint
The current target hot water temperature is displayed °C. If there is no hot water function acti-
vated, "- - -" is displayed. The current set value is here always the maximum value of all rele-
vant demands for this hot water circuit.
T-Return
The current return flow temperature of the heat generator is displayed in °C. If there is no rel-
evant sensor connected to the heat generator, "- - -" is displayed.
Flow Rate
The filtered value of the current volume flow in litres per hour is displayed.
T-HC
The inflow temperature in the direct heating circuit is displayed in °C.
T-HC Setpoint
The set temperature of the flow in the direct heating circuit is displayed in °C.
Status HS pump
The current status of the internal heat circulation pump in the Daikin Altherma EHS(X/H) is dis-
played.
Runtime Compres-
The running time of the refrigerant compressor is displayed in h.
sor
Runtime Pump
The running time of the internal heating circulation pump is displayed in h.
Mixer Position
The current position of the 3UV DHW 3-way switch valve is displayed.
0%: Position A (room heating)
100%: Position B (domestic hot water generation)
Qboh
The amount of heat in the additional heat generator for hot water generation is displayed in
kWh.
Qchhp
The amount of heat in the additional heat generator for heating mode is displayed in kWh.
Qsc
The quantity of heat in the heat pump for cooling is displayed in kWh.
Qch
The quantity of heat in the heat pump for heating is displayed in kWh.
QWP
The total amount of heat in the heat pump is displayed in kWh.
Qdhw
The quantity of heat for hot water generation is displayed in kWh.
HS type
The heat generator type Daikin Altherma EHS(X/H) detected is displayed.
Sw Nr B1/U1
The software and version of the RoCon B1 operating unit is displayed.
Sw Nr Controller
The software number and the version of the RoCon BM1 circuit board are displayed.
Sw Nr RTX RT
The software number and the version of the RTX-AL4 circuit board are displayed.
Tab. 6-12 Parameter in rotary switch setting "Info"

6.11 Exit button: Sonderfunktion

Parameter
Manual Operation
The direct heating circuit and the target hot water temperature are controlled according to the
temperature set in this parameter (see section 3.5.1).
Display of a current heat pump malfunction in the Daikin Altherma EHS(X/H). 
FA failure
If "----" is displayed there is no fault (see chapter 8).
Protocol
Display of protocol (error and information messages). Here we display the saved messages of
the Daikin Altherma EHS(X/H) and the connected data bus units with date a code, in each case
as a menu item. By selecting an entry with the rotary switch, all other corresponding information
is displayed concerning the selected fault message:
- Date and time of the message
- Code number (Information for the heating technician)
- Location (device) where the message originated
- Bus identification (device) where the message originated
Delete message
By setting this parameter to "On" and briefly pressing the rotary switch all the entries of the pro-
tocol, including the faults from connected data bus devices, are deleted.
Timeprog Reset
Resets all permanent time programmes to factory setting (see tab. 3-8).
Return
This parameter is used only to exit the special level.
Tab. 6-13 Parameter in the level "Sonderfunktion"
Operating instructions
38
Description
Description
Access
Setting range
Factory
Min / Max
setting
BE
HF
S
S
-
-
S
S
0 - 4 bar
-
S
S
0 - 100 °C
-
S
S
0 - 90 °C
-
S
S
-39 to +50°C
S
S
0 - 100 °C
-
S
S
10 - 70°C
-
S
S
0 - 100 °C
-
S
S
0 - 5100 l/h
-
S
S
0 - 100 °C
-
S
S
0 - 90 °C
-
S
S
Off
-
On
S
S
-
-
S
S
-
-
S
S
0 - 100 %
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
S
S
-
-
Access
Setting range
Factory
Min / Max
setting
BE
HF
E
E
20 - 80 °C
50 °C
E
E
-
-
E
E
-
-
E
E
Off
Off
On
E
E
Off
Off
On
E
E
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Incre-
ment
-
0.1 bar
1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
l/h
0.1 °C
0.1 °C
-
h
h
1 %
kWh
kWh
kWh
kWh
kWh
kWh
-
-
-
-
Incre-
ment
1 °C
-
-
-
-