System Settings - Daikin EHSX04P30A Operating Instructions Manual

Indoor unit for air-water-heat pumps daikin altherma integrated solar unit
Table of Contents

Advertisement

Time period
Temperature setting
Monday - Friday
Saturday, Sunday
Monday - Friday
Saturday, Sunday
Temperature setting
Monday - Sunday
Monday - Friday
Saturday, Sunday
Monday - Friday
Saturday, Sunday
Tab. 3-8 Factory setting for the permanent switching time programmes
Temporary timer programmes
For a specific situation there are 4 temporary programmes
available, which deactivate the permanent timer programmes
or the current operating mode for the duration of their validity.
The symbol of the temporary time program is displayed in the
header line of the standard display, as long as the time program
is active.
The following temporary time programmes may be
interrupted anytime by the manually change of the
operating mode.
1.
[Party]: Immediate one-off extension of the room
heating
a) If an automatic programme is activated, the last
applicable switching cycle is always extended. In the time
before switching cycle 1, the target room temperature set
in the parameter [T-Room 1 Setpoint] applies.
b) In all other operating modes, the target room temperature
set in the parameter [T-Room 1 Setpoint] applies.
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
2.
[Away]: Immediate one-off setback up to 6 hours
– The system operates in economy mode according to the
room temperature set in the rotary switch setting "Set
in the parameter [T-Absence].
Temp Night"
– The hot water generation is not affected.
– The time programme runs for the set time period after acti-
vation.
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Switching cycle 1
On
Off
Room heating / Room cooling
[T-Room 1 Setpoint]: 20 °C
"HC Program 1"
06:00
22:00
07:00
23:00
"HC Program 2"
06:00
08:00
07:00
23:00
Domestic hot water generation
[T-DHW Setpoint 1]: 48 °C
"DHW Program 1"
00:00
24:00
"DHW Program 2"
05:00
21:00
06:00
22:00
"Circulation Time"
05:00
21:00
06:00
22:00
Switching cycle 2
On
Off
[T-Room 2 Setpoint]: 20 °C
[T-Reduced]: 10 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
[T-DHW Setpoint 2]: 48 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
3.
[Holiday]: One-off calendar-controlled presence.
– The system operates exclusively in accordance with the
"Sunday" settings in the [HC Program 1].
– The hot water generation operates exclusively in accord-
ance with the "Sunday" settings in the [DHW Program 1].
4.
[Vacation]: One-off calendar-controlled reduction.
– The system only operates in economy mode according to
the room temperature set in the rotary switch setting "Set
in the parameter [T-Absence].
Temp Night"
– Hot water generation according to the set temperatures
and switching cycles in the hot water time programme
[DHW Program 1] (see section 3.4.5).
– The calendar-controlled programme [Vacation] is not
started if the operating mode [Standby] or [Manual Oper-
ation] is active on the set start date.

3.4.8 System settings

We undertake the basic settings for the Controller RoCon HP and
the system configurations for the installation environment of the
Daikin Altherma EHS(X/H), the direct heating circuit, the hot
water generation and any optionally connected components in
the rotary switch setting "Configuration"
Depending on access authority (user or expert), various different
parameters are available. Certain parameters are only acces-
sible to the heating expert.
Setting the Language, Date, Time
An internal pre-programmed calendar ensures auto-
matic time reset at the annually recurring
summer/winter time changes.
● Place the rotary switch in the "Configuration"
An overview is displayed.
3
x
Operation
Switching cycle 3
On
Off
[T-Room 3 Setpoint]: 20 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
[T-DHW Setpoint 3]: 48 °C
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
- - : - -
.
position.
Operating instructions
21