Temperature Setting Economy Mode; Temperature Setting Hot Water Generation; Unscheduled Hot Water Generation; Switching Time Program - Daikin EHSX04P30A Operating Instructions Manual

Indoor unit for air-water-heat pumps daikin altherma integrated solar unit
Table of Contents

Advertisement

3.4.4 Temperature setting Economy mode

The set room temperatures for room heating in economy mode
are determined in the rotary switch setting
● Place the rotary switch in the "Set Temp Night"
An overview is displayed.
● Select the parameter to be set with the rotary switch.
● Confirm the changes with a brief push of the rotary switch.
– [T-Reduced]: Set value for "Reducing" operating mode or
setback by a permanent timer programme.
– [T-Absence]: Set value for temporary heating / cooling
programmes ("Away" and "Vacation").
Settings are displayed.
● Set the temperature.
● Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.6.

3.4.5 Temperature setting hot water generation

The hot water set temperatures for hot water generation for each
individual timer programme are determined in the rotary switch
setting
.
● Place the rotary switch in the "DHW Set Temp"
The end figures of the parameter designations (1 - 3)
within this rotary switch setting designate the associ-
ation with each individual cycle of the timer programme.
● Select the temperature block to be set with the rotary switch.
● Confirm the changes with a brief push of the rotary switch.
Settings are displayed.
● Set the temperature.
● Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.7.

3.4.6 Unscheduled hot water generation

You can charge the hot water up manually outside a hot water
timer programme to the preset temperature set in parameter 
[T-DHW Setpoint 1] in the rotary switch position
is carried out as a priority and independently of any other heating
programmes.
● Place the rotary switch in the "DHW Install"
An overview is displayed.
● Select the parameter to be set with the rotary switch.
– [1x Hot Water]: Activating one-off hot water generation.
● Confirm the changes with a brief push of the rotary switch.
● Setting parameters
● Confirm the changes with a brief push of the rotary switch.
Begin unscheduled hot water generation.
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
.
position.
Possible setting values for this rotary switch setting can be seen in chapter 6.3.

3.4.7 Switching time program

Various different timer programmes are available, that are set in
the factory, but which can be adjusted to suit, to provide conven-
ient and individual room and hot water temperature control.
The timer programmes regulate the associated heating circuit,
the storage tank charging circuit and an option connected circu-
lation pump in accordance with the stipulated switching times.
Adjustment
In the rotary switch position
the heating circuit, the integrated hot water generation and the
optional circulation pump.
position.
● Place the rotary switch in the "Time Program"
position.
● Select the timer programme to be set with the rotary switch.
● Confirm the changes with a brief push of the rotary switch.
● Select and change the value to be set with the rotary switch.
● Confirm the changes with a brief push of the rotary switch.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in chapter 6.8 "Rotary switch setting: Time Program".
Permanent timer programmes
For the connected heating circuits and the storage tank charging
circuit, timer programmes regulate the heating circuit tempera-
tures or the operating times for the circulation pump in ac-
cordance with the stipulated switching cycles. The switching
cycles are saved in time blocks for which various set tempera-
tures apply.
In the switching cycles the heating system is regulated differen-
. Heating up
tiated into day and economy mode.
The target room temperatures for these timer programmes are
set in "Set Temp Day"
position.
Set Temp"
The following switching time programmes are available:
– 2 timer programmes for the heating circuit, each with 
3 possible time cycles
– [HC Program 1]
– [HC Program 2]
After this temporary function has expired, the Controller
automatically jumps back to the previously active oper-
ating mode. The rotary switch should therefore be re-
turned to the position "Info"
The function is subject to time limits.
It will be suspended at the latest after the maximum
charging time set by the technician and can only be re-
started after the expiration of the blocking time set by
the technician at the earliest.
An overview is displayed.
Settings are displayed.
, "Set Temp Night"
.
A separate input for each individual day of the week is
possible, or in blocks of "Monday to Friday", "Saturday
to Sunday" and "Monday to Sunday".
3
x
Operation
after activation.
we set the time intervals for
and "DHW
Operating instructions
19

Hide quick links:

Advertisement

Table of Contents
loading