Final Shutdown - Daikin EHSX04P30A Operating Instructions Manual

Indoor unit for air-water-heat pumps daikin altherma integrated solar unit
Table of Contents

Advertisement

5
x
Decommissioning

5.2 Final shutdown

WARNING!
Cooling systems (heating pumps), climate control
systems and heating devices that are incorrectly dis-
mantled can both endanger the life and health of
people and exhibit impaired function during start-up.
● Work on the Daikin Altherma EHS(X/H) (such as
dismantling components, temporary or final
shutdown of system) is only to be carried out by
persons who are authorised and who have
successfully completed qualifying technical or
vocational training and who have taken part in
advanced training sessions recognised by the
relevant responsible authorities. These include, in
particular, certified heating engineers, qualified
electricians and HVAC specialists, who on
account of their professional training and expert
knowledge, have experience in the professional
installation and maintenance of heating, cooling
and air conditioning systems and heat pumps.
● You must observe the warning and safety
instructions in the installation manual on working
in the coolant system.
A final shutdown may be necessary if
– the system is defective and is being dismantled and disposed
of.
– components of the system are defective, and are being dis-
mantled and replaced.
– the system or parts of the system are being dismantled and
reassembled in another location.
The Daikin Altherma EHS(X/H) is designed to be environmentally
friendly and easy to install: the jobs described above can
therefore be carried out in an efficient and environmentally-
friendly manner.
When changing location or replacing parts on the coolant system
in the pipe network:
● Pump the coolant back into the external heat pump unit (see
installation and operating guide for the particular external
heat pump unit).
When disposing of the machine or replacing parts in the coolant
system:
● Suction the coolant from the machine and recycle (see instal-
lation and operating guide for the particular external heat
pump unit).
Operating instructions
32
CAUTION!
Coolant escaping from the system causes long-term
damage to the environment.
Mixing different kinds of coolant can result in hazard-
ous toxic gases being released. Mixing with oils when
coolant escapes can lead to the soil being contami-
nated.
● Never allow coolant to be released into the atmos-
phere - always suction it off and recycle using a
suitable recycling device.
● Always recycle coolant, in so doing keeping it
separated from oils and other additives.
● Only store different types of coolant separately, in
suitable pressure vessels.
● Dispose of coolants, oils and additives properly
and in accordance with the applicable national
regulations of the country it is being used in.
● Decommissioning a Daikin Altherma EHS(X/H) (see
section 5.1).
● Disconnect the Daikin Altherma EHS(X/H) from all electrical
connections, coolant and water connections.
● Dismantle the Daikin Altherma EHS(X/H) or components in
accordance with the installation guide in reverse order.
● Daikin Altherma EHS(X/H) disposed off in a professional
manner.
Recommendations for disposal
The Daikin Altherma EHS(X/H) has an environmentally-friendly
design. During the disposal process, the only waste created is
that which can be used for material or thermal recycling. The ma-
terials used that are suitable for recycling can be sorted into indi-
vidual types.
Daikin has complied with the standards for environmen-
tally-friendly disposal as a result of the environmentally-
friendly design of the Daikin Altherma EHS(X/H).
Proper disposal in compliance with the respective
national regulations of the country of use is the respon-
sibility of the user/owner.
The designation of the product means that electrical
and electronic products may not be disposed of
together with unsorted domestic waste.
Proper disposal in compliance with the respective
national regulations of the country of use is the respon-
sibility of the user/owner.
– Disassembly of the system, handling of coolant,
oil and other parts may only be carried out by a
qualified fitter.
– Disposal may only be carried out by an organi-
zation that specialises in reuse, recycling and
recovery.
Further information is available from the installation
company or the responsible local authorities.