Displaying the water pressure
On the Controller RoCon HP, when it is switched on, you can
display the system pressure (water pressure) in the internal
circuit (direct heating circuit). The water pressure is available as
the first info parameter (see fig. 3-6).
The permissible range of water pressure during operation de-
pends on the Daikin Altherma EHS(X/H) and the heating system.
The set values and threshold values must only be changed by the
heating technician. If the water pressure falls below the minimum
value (set parameter value), it must be increased by topping up
the system (see chapter on "Inspection and Maintenance").
Fig. 3-6
Info values display (e.g. system pressure)
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Info
Overview
Water Pressure
T-HS
Water Pressure

3.4.2 Setting the operating mode

The selection of the operating mode with which the Daikin
Altherma EHS(X/H) is to operate is undertaken on the rotary
switch in the setting "Operating Mode"
The selected operating mode is activated by briefly pushing the
rotary switch.
Operating Mode
Standby
Reducing
Fig. 3-7
Switching the operating mode
(e.g.: from "Standby" to "Automatic 1")
● Place the rotary switch in the "Operating Mode"
position.
An overview is displayed.
● Select the desired operating mode with the rotary switch.
● Confirm the changes with a brief push of the rotary switch.
Daikin Altherma EHS(X/H) operates in accordance with
the set operating mode.
The current operating mode is indicated by an appropriate
symbol in the standard display.
Operating mode Standby (Stand-by)
CAUTION!
A heating system that is not frost-protected can freeze
in cold weather and may be damaged.
● Drain the water out of the heating system if there is
a risk of frost.
● If the heating system is not drained and there is a
risk of frost, the power supplies must be secured
and the external main switch must remain switched
on.
In this mode, the Daikin Altherma EHS(X/H) is shifted to the
stand-by mode. The frost-protection function (see
section 3.6.5) remains in place. In order to maintain this function,
the system must not be disconnected from the mains!
All controllers integrated into the RoCon-system via the CAN bus
are also switched at a higher level to the operating mode
"Standby".
3
x
Operation
.
Operating Mode
Heating
Cooling
Summer
Operating Mode
Summer
Automatic 1
Automatic 2
Operating Mode
Summer
Automatic 1
Automatic 2
Operating instructions
17