Connecting the camera and personal computer via network......16 Using the camera search application "Webcam IP Manager" ......18 Login dialog ......................20 Viewing and listening..................21 Resolution ......................24 Configuration....................25 Compression ......................25 Network settings....................28 9.2.1 Basic ....................29 9.2.2 DDNS Settings..................31 Siemens AG A6V10334045 22.12.2011...
Page 4
System........................59 9.10.1 Settings ....................59 9.10.2 Update....................60 9.10.3 Configuration..................60 9.10.4 Temperature..................61 9.10.5 Test .....................61 9.11 Log........................63 9.12 Notice .........................64 Utility program application................65 10.1 NAS player setup....................65 10.2 Audio recording setup..................65 10.3 Firmware update setup..................65 Maintenance......................67 Disposal......................68 Index Siemens AG A6V10334045 22.12.2011...
About this document Content of document 2 About this document Content of document This document contains information on the configuration of the product. Meaning of symbols Orientation guide [-> 3] Cross-reference Save Button <Ctrl> Tips and information Siemens AG A6V10334045 22.12.2011...
Mobile: +47 9287 3010 Denmark Tel.: +45 46 33 82 14 Finland Tel.: +35 85 0361 3909 Siemens AG provides training courses for all products. Target group Commissioning personnel Configure the product at the Has obtained suitable specialist training for the place of installation according to function and for the products.
The following conditions may be observed when using a CMOS camera. These are inherent in the design and do not stem from any fault in the camera itself. Vertical smear: This phenomenon occurs when viewing a very bright object. Siemens AG A6V10334045 22.12.2011...
Page 8
This is a fixed pattern, which may appear over the entire monitor screen when the camera is operated at a high temperature or in a low luminance environment. Jagged picture: When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged. Siemens AG A6V10334045 22.12.2011...
EU-directives 4 EU-directives This product complies with the requirements of the following European directives. The EU declaration of conformity is available to the responsible agencies at: Siemens AG Industry Sector Building Technologies 76181 Karlsruhe Germany European Directive 2004/108/EC „Electromagnetic Compatibility”...
Technical data 5 Technical data CVMS2025-IR Type 2 MP Day/Night IR Vandal Dome Camera vImage sensor 1/3” 1080p HD CMOS image sensor OV2715 Effective pixels 1920 (H) x 1080 (V) Image compression method H.264 / MPEG4 / Motion JPEG (triple...
Page 11
UpnP, CIFS, NFS, IEC802.1x, ONVIF Mechanical Protection rating IP66 (with surface cable entry) Resistance to shock IK10 (Concealed cabling or surface cabling in metal conduit DIN EN 50086, installation closed.) Dimensions (DxH) 140 mm x 115 mm Weight 1.2 kg Siemens AG A6V10334045 22.12.2011...
Details for ordering Package contents 6 Details for ordering Type Order No. Designation CVMS2025-IR S54561-C95-A7 1/3'' IP Vandal Dome, 2MP, Day / Night, IR-Illuminators Further products and accessories can be found in the internet: www.siemens.com/securityproducts Package contents IP dome camera...
Camera part and connector definition Camera part definition 7 Camera part and connector definition Camera part definition 72,3 36,2 Ø6 Ø6 Unit: mm Dome cover Locking screw Camera module IR Led’s Camera housing Lens Connector pin definition Siemens AG A6V10334045 22.12.2011...
Buzzing noises may come from inside. This does not indicate malfunction. Using the power adapter near a radio, TV, or cell phone may cause interference. Use the adapter at sufficient distances from these devices. Siemens AG A6V10334045 22.12.2011...
Connecting the camera and personal computer via network IP address To connect to the network, the administrator needs to set the network camera IP address. There are two options to set the IP address. Entering an IP address manually (factory default) Siemens AG A6V10334045 22.12.2011...
Page 17
Setting the IP address of the personal computer. Use a free IP address (other than 192.168.0.10, which is the camera's IP address). For example., set the IP address to 192.168.0.20 (and the subnet mask to 255.255.255.0). Siemens AG A6V10334045 22.12.2011...
Do not install "Webcam IP Manager " with other operating systems. Using "Webcam IP Manager " to search for a camera Set the personal computer to “Administrator authorization“ when using “Webcam IP Manager”. 1. Select "Start" > "Programs" > "Webcam IP-Finder". Siemens AG A6V10334045 22.12.2011...
Page 19
1. Start the Web-Cam IP Manager by loading IP Manager.exe. This application is found on the CD included with delivery. The Web-Cam IP Manager program window will open: Siemens AG A6V10334045 22.12.2011...
A person who has logged in as an administrator can perform all functions. Administrator login 1. Search for the camera using the "Webcam IP-Finder", double-click the camera you wish to log in to. The login dialog will appear. Siemens AG A6V10334045 22.12.2011...
"Administrator authorization." Browser settings when proxy server is used If a proxy server is used, setting the browser to bypass the proxy server during communication with the network camera is recommended. Siemens AG A6V10334045 22.12.2011...
Page 22
If the network cameras are used in conjunction with a proxy server, it may take some time for the images to be displayed after a login, or the frame rate of the de- livered images may be reduced. All browsers except the IE only support image viewing and compression setting. Siemens AG A6V10334045 22.12.2011...
Page 23
R: Remote control to execute preset settings and basic lens adjustments such as focus and zoom in/out. Before you execute this function, please set the baud rate and address of the telemetry device for control via RS485 port. Siemens AG A6V10334045 22.12.2011...
Cropping and E-zoom are mutually exclusive. Only resolution in group 1 (except SVGA) and normal stream number less than 2 (including number 2) can own E-zoom feature. OSD & Regular features of normal streams Mask zone Siemens AG A6V10334045 22.12.2011...
Image mode 3 streams can be selected. Stream 1, stream 2 and stream 3 can be set to H.264, JPEG and MPEG4. No codec can be selected twice. All resolutions H.264, JPEG and MPEG4 are possible. Siemens AG A6V10334045 22.12.2011...
Page 26
3fps: GOP 1~9 – 2fps: GOP 1~6 – 1fps: GOP 1~3 Profile: You can choose between Baseline, Main profile and High profile. JPEG - The following settings are enabled when "Image Mode" is set to "JPEG". Siemens AG A6V10334045 22.12.2011...
Page 27
Low: This setting produces highest image quality. The file size increases. Quality value is set to 31. – Mid-low: 24 – Standard: 16 – Mid-high: 9 – High: This setting produces lowest image quality. The file size decreases. Quality value is set to 1. Siemens AG A6V10334045 22.12.2011...
The frame rate value for each cropping can be set between 1 and 5 fps. Network settings You can configure your basic camera settings, DDNS, FTP server, RTSP, HTTPS, IEEE802.1X, SNMP & 3GPP by selecting "network setting" in the "Configuration" menu. Siemens AG A6V10334045 22.12.2011...
Default Gateway: Leave blank. It is not necessary to enter a Default Gateway if it is not used. Ask your Network Administrator for information on the default gateway. Primary DNS: (same as above) Secondary DNS: (same as above) Siemens AG A6V10334045 22.12.2011...
Page 30
When “ON” is selected, the camera can be detected automatically by the Internet Explorer browser. It is not necessary to have the Web cam IP manager installed. AUDIO output When “ON” is selected, a voice message indicating camera’s IP address can be delivered to a headphone. Siemens AG A6V10334045 22.12.2011...
2. Select the number of maximum connections from the "Max Simultaneous Connections" list box. Click “Save” to save your settings. This function is used to download directories/files to or to delete them from the SD memory card. Siemens AG A6V10334045 22.12.2011...
9.2.5 HTTPS Here you can upload a certificate. Click “Browse”. A window will pop up. Select the file you want to upload. Click upload to upload the file. 9.2.6 IEEE802.1X Certificate: 1. Click” Browse” Siemens AG A6V10334045 22.12.2011...
Page 33
Private key password: Enter your private key password. Enable IEEE 802.1X: Select "ON" to enable it or "OFF" to disable it. Select "ON" to enable SNMP V1, SNMP V2C and SNMP V3, respectively, or select "OFF" to disable them. Siemens AG A6V10334045 22.12.2011...
2. Select "Basic" in the sub menu. – The "Camera - Basic Settings" dialog will appear. 3. Configure the individual settings. – Click "Save" to save your settings. The settings will not be applied unless "Save" is clicked. Siemens AG A6V10334045 22.12.2011...
Page 35
Only active if not linked to alarm input. Day-Night Delay Time: Choose the day-night delay time from 0, 5, 10, 15, 30. Day-Night Level: Choose the day/night level: Low, Mid, High. IR Level: Set this option to “OFF” or “AUTO”. Siemens AG A6V10334045 22.12.2011...
Page 36
In this case, set the area so that the portion wished to see enters the selected area. The area size is roughly as follows. Siemens AG A6V10334045 22.12.2011...
Page 37
Select "ON" to activate or "OFF" to deactivate the flip function. Picture Mirror: The selected image will be side-inverted. Select "ON" to activate or "OFF" to deactivate the mirror function. Siemens AG A6V10334045 22.12.2011...
The cropping size of width and height must be multiple of 32. Ex: 320*160. The smallest cropping size will be 128*128. At least a resolution that should be set in VGA or D1. 9.3.3 Camera cropping settings Siemens AG A6V10334045 22.12.2011...
Page 40
5. Click “OK” to save and finish the settings. 6. Click “Save” to save your settings. Select free size 1. Click on one corner of the window and drag it to the desired size 2. Click “OK” to save and finish the settings. Siemens AG A6V10334045 22.12.2011...
An enabled motion sensor will trigger an alarm a change on a screen is detected. On the rear panel, there are 3 digital alarm inputs (AL1, AL2, AL3). Before using the alarm function, you need to define some parameters. Siemens AG A6V10334045 22.12.2011...
Page 42
Pre-recorded voice files with the extension .wav that have been uploaded to the SD memory card can be selected as alarm messages. Up to 10 audio sources can be selected. 7. Actions Default is OFF, preset can be selected 1~16. Siemens AG A6V10334045 22.12.2011...
Page 43
2. Output hold time: Set a time to hold the alarm output. You can select 0, 5, 10, 15, or 30 seconds. This function is used when a siren, buzzer or emergency light is connected. Siemens AG A6V10334045 22.12.2011...
5. Motion Alarm Message: Enter a message text. This text must not be longer than 64 characters. When a motion event occurs, the alarm server will receive this message text. Siemens AG A6V10334045 22.12.2011...
Configuration Recording Recording 9.5.1 FTP Recording Siemens AG A6V10334045 22.12.2011...
Page 46
You can save your image files generated by scheduled recording, alarm recording, or motion-triggered recording. Scheduled Recording Select the recording condition in the recording schedule table for all days from Monday to Sunday: Stop, All Day, Schedule 1 or Schedule 2. Recording by Alarm Siemens AG A6V10334045 22.12.2011...
Page 47
FTP Connecting Method: Reconnect - The network camera logs in/out for each file transfer; Continuous Connection - The network camera is always connected. Connecting method You can choose to save your image files to either FTP server 1 or FTP server 2, or automatically switch between servers. Siemens AG A6V10334045 22.12.2011...
Overwrite: When set to "ON", the images stored on the SD card will be overwritten when the capacity of the SD card has been reached, starting with the oldest files. 9.5.2 SD recording Siemens AG A6V10334045 22.12.2011...
Page 49
JPEG format, no need for MPEG4 format 6. Recording time If MPEG4 selected, please set the recording from 2,5,10s. Recording by Motion Prerequisite: Motion detection has been configured. All other settings are the same as for recording by alarm (see above). Siemens AG A6V10334045 22.12.2011...
When the overwrite mode is set to “ON”, files will be deleted starting with the oldest files. If important data needs to be saved, set the overwrite mode to “OFF”. 9.5.3 Email recording You can receive images if you have set up your email account. Siemens AG A6V10334045 22.12.2011...
Page 51
Configuration Recording Set the conditions for sending email according to a schedule If "Schedule" is selected 1. Subject – Enter a subject title for the email to be sent. Siemens AG A6V10334045 22.12.2011...
Page 52
3. Password – Enter your email account's password. 4. Password (Confirm) – Confirm your email password. 5. Administrator email Address – Enter your email address. 6. Click "Save & Test Email” to save and test your email settings. Mail to address list Siemens AG A6V10334045 22.12.2011...
Recording You can send emails to multiple users according to schedule, or when an alarm is triggered or a motion is detected. 9.5.4 NAS recording This is a method to store data on network-based storage devices. Siemens AG A6V10334045 22.12.2011...
Page 54
Server, User ID, Password and Path text fields, respectively. 5. Click “Save” to complete the NAS setup procedure. Make sure all NAS devices are available in network before activating this function. Siemens AG A6V10334045 22.12.2011...
Audio Output Level: – HIGH - Increases the audio output level. – MIDDLE - Adjusts the audio output level to a medium level. – LOW - Reduces the audio output level. Siemens AG A6V10334045 22.12.2011...
– Synchronization from PC: The system date/time can be synchronized via the PC settings. Daylight Select "ON" to activate the daylight-saving function if you are in a daylight- saving time zone (effective for NTP mode only). Siemens AG A6V10334045 22.12.2011...
ID and password by the system administrator. You can add users by assigning them individual IDs and passwords in the "User Settings" field and adding them to the user list. User level: Siemens AG A6V10334045 22.12.2011...
Allowed: The listed IP addresses will pass the firewall. Denied: The listed IP addresses will be rejected by the firewall. 9.9.2 Forbidden ports All the listed ports that enabled (set to "ON") will be rejected by the firewall. Siemens AG A6V10334045 22.12.2011...
CGI-commands. If you select "ON", you always have to enter an ID and password for the web page. You can change everything using the cgi- commands. If "OFF" is selected, you will have no access. Siemens AG A6V10334045 22.12.2011...
Do not disconnect power during a SW update. Otherwise, it causes SW update failure and you have to send back your camera to Siemens maintenance. 9.10.3 Configuration Camera configuration information can be exported and saved to a personal computer.
If “0” is selected, the e-mail will be delivered only once. When the temperature of the camera is too high, for example above 70°C,a warning message will pop up. 9.10.5 Test The status of the system can be displayed here. Siemens AG A6V10334045 22.12.2011...
Page 62
Configuration System Siemens AG A6V10334045 22.12.2011...
Configuration 9.11 Event log Select the menu sequence Settings > Log. By clicking the buttons “Display All Logs”, “Display System Logs”, “Display User Logs”, "Delete logs" the corresponding logs will be displayed and can be processed. Siemens AG A6V10334045 22.12.2011...
3. Click on the red button and start recording your voice. 4. Click "Stop". 10.3 Firmware update setup This application is found on the DVD that is included in the delivery. You can update multiple network cameras simultaneously. To update firmware, proceed in the following manner: Siemens AG A6V10334045 22.12.2011...
Page 66
100 network cameras. 3. Click on "Browse…" and select the software version for the network camera. 4. Click on "Upload" to start the firmware update. Current FW version : X.2.2.984 Siemens AG A6V10334045 22.12.2011...
Do not touch the lens area. If the surface is touched accidently use a soft cloth moistened with alcohol to clean it. Defective modules should be sent to the nearest Siemens office to be forwarded to the service centre. Siemens AG A6V10334045 22.12.2011...
It is a precondition for reuse and recycling of used electrical and electronic equipment. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product. Siemens AG A6V10334045 22.12.2011...