Oil Filter/Oil Pump; Testing Oil Pump Pressure - KYMCO MXU400 Service Manual

Hide thumbs Also See for MXU400:
Table of Contents

Advertisement

2. Using a suitable block, support the rear of the tank
and connect the gasline hose to the gas tank valve
outlet. Secure with a clamp.
3. Remove all blocking and secure the gas tank with
the cap screw. Tighten securely.
4. Secure the rear of the front body to the frame with
the cap screws (A) and tighten securely; then
install the gas tank cover and secure with the rein-
stallable rivets (B).
4-10
KC252A
5. Install the side panels and seat making sure it locks
securely in place. Turn the gas tank valve to the
ON position and check for leaks.

Oil Filter/Oil Pump

NOTE: Whenever internal engine components
wear excessively or break and whenever oil is con-
taminated, the oil pump should be replaced. The
oil pump is not a serviceable component.
Testing Oil Pump
KC241A
1. Connect the Tachometer to the engine.
2. Connect the Oil Pressure Test Kit to the oil filter
drain plug.
KC225A
Pressure
KC219A
KC195A