3.13.15 Send Characters
You can enter up to two characters in hexadecimal representation in the parameters "sendchar." If a
character received on the serial line matches one of these characters, it is sent immediately, along with any
awaiting characters, to the TCP connection. This minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT, etc.). Setting the first sendchar to 00 disables the
recognition of the characters. Alternatively, the two characters can be interpreted as a sequence (see
on page 3-30).
Control
3.13.16 Telnet Terminal Type
This parameter appears only if the terminal type option is enabled in Disconnect Mode (see
on page
above). If this option is enabled, you can use the terminal name for the Telnet terminal type.
3-28
Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and binary options,
which can be used for applications like terminal emulation to IBM hosts.
3.13.17 Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in Disconnect Mode (see
on page 3-28). If the option is enabled, you can set a password on the serial port.
DisConnMode
3.14 E-mail Settings
The configurable pin option for triggering e-mail is NOT used on this product. The configurable pins are
used for other purposes.
The only method available for e-mail triggering is to use the two-byte serial string to initiate a trigger.
Note: You can change these settings via Telnet or serial connections only, not on the Web-Manager. To configure e-
mail settings via DeviceInstaller, see E-mail Notification in the DeviceInstaller User Guide.
Note: The configurable pins CP0, CP1 and CP2 CANNOT be used to trigger E-mail.
***************** E-mail *****************
Mail server (0.0.0.0) (000) .(000) .(000) .(000)
Unit name ():
Domain name ():
Recipient 1 ():
Recipient 2 ():
- Trigger 1
Enable serial trigger input (N) ?
Trigger input1 [A/I/X] (X) ?
Trigger input2 [A/I/X] (X) ?
Trigger input3 [A/I/X] (X) ?
Message ():
Priority (L):
Min. notification interval (1 s):
Re-notification interval (0 s):
*** Trigger 2
Enable serial trigger input (N) ?
Trigger input1 [A/I/X] (X) ?
Trigger input2 [A/I/X] (X) ?
Trigger input3 [A/I/X] (X) ?
Message ():
Priority (L):
Min. notification interval (1 s):
Re-notification interval (0 s):