Power Up/System Reset

NOTE: LED display keypads supported by the XL-2T control panel include: XK-406, XK-508, XL-
4600RM, XL-4600SM, and 6615. LCD display keypads supported by the XL-2T include: XK-5LC,
and XK-7LC.
SYSTEM STABILIZATION MODE: Upon power up of the system and after completion of
system programming, IF THE SYSTEM WAS PREVIOUSLY ARMED, all the lights on the
LED keypad(s) will turn ON momentarily or, in the case of an LCD display installation, the
keypad(s) will display STANDBY! momentarily. THE KEYYPAD DISPLAY WILL THEN
RETURN TO NORMAL. HOWEVER, THE ZONES WILL NOT RESPOND TO ALARM
CONDITIONS FOR APPROXIMATELY 2 MINUTES. THIS 2 MINUTE DELAY CAN BE
DISABLED BY SIMPLY ENTERING A VALID USER CODE which disarms the system and
reduces the power up reset time to approximately 5 seconds. The 2 minute interval is used to
allow motion detectors (interior zones) to stabilize in order to prevent false alarms. Upon
system power up, IF THE SYSTEM WAS PREVIOUSLY DISARMED, the power up reset
time will be approximately 5 seconds. If total system power is lost, upon power restoral, the
system will return to its previously armed state.

Arming the System

The system can be armed only if all burglary zones are not faulted:
TO ARM:
Enter any programmed four digit user code. NOTE: The factory default for user #1 is 1234.
The ARMED LED will light and the user may exit through an exit/entry zone for the time
period programmed as the exit delay.
LCD display keypads will indicate the following message:
The system can be armed without the backup battery being connected, however the AC/LB
or BAT light will flash depending on the keypad used.

Stay Arming

TO ARM: Press the STAY key followed by a four digit user code.
This will arm the system with all programmed interior zones excluded.
on LED display keypads this requires that the READY LED be ON
on LCD display keypads, the following message will appear:
SYSTEM: READY
ON: AWAY
EXIT NOW
On LED display keypads the STAY and ARM LEDs will light continuously.
LCD display keypads will indicate the following message:
ON: STAY
EXIT NOW