Section 1. Introduction; Introduction - FBII XL-2T Installation And Setup Manual

Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Introduction

The XL-2T is a state of the art microprocessor-based control/communicator. The system
features seven (7) fully programmable zones. Programming can be performed through any of
the compatible keypads or the system can be uploaded and downloaded remotely using the
EZ-Mate PC Downloader Software. Additionally, the software can be programmed to control
remote actions, such as arming, disarming, bypassing, etc. Programming options are stored
in an Electrically Erasable Programmable Read Only Memory (EEPROM). The EEPROM is
non-volatile, meaning that programmed instructions will not be lost in the event of a loss of
power.
Features of the XL-2T include:
• 7 Zones (all fully programmable including Key switch)
• 15 User Codes (Ambush, Arm Only & Door Strike Capability)
• Keypad Programming and Remote Programming via PC and Modem
• Upload/Download and remote commands with answering machine override capability
• 3 methods of Uploading/Downloading: PC operator initiated, Unattended
Downloading & On-line Downloading
• Optional Built-in 2-Tone siren driver or Conventional Bell Output
• Auto Arming at a specific time of day with capability to arm in either Away, Stay or
Instant Modes
• Dual Entry Timers
• 78 Event History Log (Alarms, Troubles, Low Battery, Bypasses, Control Station (CS) Test,
Openings & Closings)
• 3 Emergency Keypad Conditions (Panic, Fire & Auxiliary)
• 2 Programmable Trigger Outputs
• Real Time Clock (Displays Time & Date via LCD Keypad) with reminder when clock needs
to be set
• CS Test Timer by Event, Time or Both (1 Hour, 1, 7, 27, 60, 90 Days)
• Customer Control of Chime Mode
• Quick Arming, Quick Bypass and Quick Force Arming
• CS Reporting by Zone
• False alarm prevention features: Cross Zone, Exit Error, Recent Close, Swinger Shutdown
Cancel Code & System Stabilization during power up
• Arming by Keyswitch in Away or Stay Modes
• Keypad Tamper/Lockout with optional CS Reporting
• Restore Transmission options: After Loop or After Bell
• Fire Zone Reset through keypad
• Glass Break Reset through keypad
• Bell Test, Low Battery Test, AC Loss and Communications Failure
• Input Power: 12VAC, 20VA; 12VDC, 4-7AH
• Output Power: 12VDC, 500mA
• Bell Output Power: 12VDC, 1A