Section 3. System Wiring And Hookup; System Wiring Diagram - FBII XL-2T Installation And Setup Manual

Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

System Wiring Diagram

XL-2T
WARNING
:
To prevent risk from
electrical shock, de-
energize the system
control unit and
disconnect the
telephone lines
before servicing
this unit.
1
ZONE 1
2.2k
2
2.2k
ZONE 2
3
4
ZONE 3
2.2k
5
2.2k
ZONE 4
6
7
ZONE 5
2.2k
8
2.2k
ZONE 6
9
2.2k
10
11
EARTH GND.
(SEE NOTE 1)
KEYPAD
(SEE NOTE 6)
SYSTEM STABILIZATION MODE: Upon power-up of the system and after completion of system
programming, all the lights on the LED keypads will flash momentarily and the LCD keypads will display
STANDBY! momentarily. EACH KEYPAD DISPLAY WILL THEN RETURN TO NORMAL. HOWEVER,
THE ZONES WILL NOT RESPOND TO ALARM CONDITIONS FOR APPROXIMATELY 2 MINUTES.
The 2 minute interval is used to allow motion detectors (interior zones) to stabilize on power-up in order to
prevent false alarms. THE 2 MINUTE RESPONSE TIME CAN BE DISABLED BY SIMPLY ENTERING
A VALID USER CODE which disarms the system and reduces the power-up reset time to approximately 5
SECONDS.
NOTE: If total system power is lost, then upon power restoral, the system will return to the previously
armed state.
System Wiring And Hookup
SYSTEM DEFAULT
JP1
RESET JUMPERS
NOTES:
1. Connect to a grounded metal water pipe (16ga. at 15 ft.).
2. Total AUX. power available (including keypad power) is 500mA max. (180mA for fire installations).
Used for connection of devices rated from 11.5 to 13.1VDC. All circuits are power limited.
3. System must be tested on a weekly basis. For information, refer to manual.
4. Do not connect the transformer to a switch-controlled receptacle. Power varies with transformer (SEE NOTE 2).
5. Installation of equipment and wiring methods are required to be in accordance with the National Electrical code
and ANSI/NFPA No. 72, Chapter 2.
6. Maximum of 4 keypads of LED type or LCD type.
7. Limited energy cable must be used.
8. Maximum for UL installations: Entry Delay, 45 sec.; Exit Delay, 60 sec.
9. For connection of VS-299 Siren Driver. Constant positive (+) unregulated output.
10. Programmable trigger outputs. If used for smoke detector power reset see Detail A.
See manual for programming information. Use model XL-2GTC trigger cable.
11. 24 hr battery standby is required for fire installations. 4 hr battery standby is
required for emergency/burglary.
12. System must be checked by a qualified technician once every three years.
AUX POWER
SMOKE DETECTOR POWER
12VDC Reg., 500mA max.
(9.1-12.6VDC,
(SEE NOTE 2)
50mA max.)
+
+
12 13 14 15 16 17 18
19 20 21 22 23 24
MODEL 368 CORD
TO RJ31X OR
CA31A JACK
HOME
TELCO
CONNECTIONS FOR HOUSEHOLD FIRE/BURGLAR ALARM SYSTEM
To re-load factory default values, remove all power
JP2
(AC & DC). Short JP1 to JP2. With short still applied,
re-apply power (AC then DC), wait 5 seconds, then
remove short with power still applied.
F3
F2
AUX
F1
BELL
DC POWER (+)
10-15.5VDC
(SEE NOTE 9)
TRIGGER OUTPUTS
(SEE NOTE 10)
25
P1
FIRE & BURGLARY
TRANSFORMER
ALARM OUTPUT
12VAC, 20VA
(11.5-13.1VDC, 1A max.)
(Connect to 24 HR.
650mA UL
120VAC, 60 Hz Outlet
INSTALLATION
SEE NOTE 4)
+
-
BELL
+
-
+
SPEAKER
S E C T I O N
(PER UL STANDARDS UL985 AND UL1023)
DETAIL A
CONTROL PANEL
POWER
21 16
1
2
BAT
MODEL ESL2048
+
EOL RELAY
4A
BATT
1A
_
BAT
3A
UL INSTALLTIONS REQUIRE LISTED
END-OF-LINE DEVICE. USE RESISTOR
FROM EOL22 KIT. LOOK FOR LISTING
MARK ON ITEM.
WARNING:
NOTE: UL VERSIONS
CONTAIN PTC's IN
THIS UNIT INCLUDES AN ALARM
PLACE OF FUSES
VERIFICATION FEATURE THAT WILL
RESULT IN A DELAY OF THE SYSTEM
ALARM SIGNAL FROM THE INDICATED
CIRCUITS. THE TOTAL DELAY (CONTROL
UNIT PLUS SMOKE DETECTOR) SHALL
NOT EXCEED 60 SECONDS. NO OTHER
INITIATING DEVICES SHALL BE CON-
NECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY
12V, 4-6AH
HAVING JURISDICTION.
BATTERY
MODEL 1240A
CIRCUIT
CONTROL UNIT
(SEE NOTE 11)
(ZONE)
DELAY-SEC
20
_______
_____
PRODUCT COVERED UNDER
US PATENT #4,791,658
3
SMOKE DETECTOR
9.5 - 12.2VDC
ZONE
LISTED
HOUSEHOLD
3
4
THERMOSTAT
ESL104
UL LISTED
SMOKE
DETECTOR
MODEL
ESL445AT
2.2k EOL RESISTOR
SMOKE DETECTOR
MODEL DELAY-SEC
______
______ __________
3–1