Section 2 - System Wiring And Hookup; System Wiring Diagram - FBII XL-1S Hookup And Installation Instructions

Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

System Wiring Diagram

CONNNECTIONS FOR HOUSEHOLD FIRE/BURGLAR ALARM SYSTEM
XL-1S
NOTES:
1. Connect to a grounded metal water pipe (16ga. at 15 ft.)
2. Total AUX. power available (including keypad power) is 500mA max
TERMINALS
ZONE
(+)
(-)
3. System must be tested on a weekly basis. For information, refer to manual.
1
2
1
4. Do not connect the transformer to a switch controlled receptacle.
3
2
2
5. Installation of equipment and wiring methods are required to be in accordance
4
5
3
4
6
5
6. Battery capacity for Emergency Standby is a minimum of 4 hours.
7
5
PANIC
7. Maximum of 4 keypads. Available keypads include: XK-104 and 6805.
1
8. Limited energy cable must be used.
ZONE 1
2.2K
9. Non-replaceable fuse (F3). Return to manufacturer if blown. Do not solder in field.
2
10. Maximum for UL installations: Entry Delay, 45 sec.; Exit Delay, 60 sec.
2.2K
ZONE 2
11. For connection of VS-299 Siren Driver. Constant positive (+) unregulated output.
3
12. The PANIC or KEYSWITCH connected to terminals 5 & 7 is to be no more than 3 ft.
4
ZONE 3
13. Programmable trigger outputs. If used for smoke detector power reset
2.2K
5
2.2K
ZONE 4
6
7
PANIC
8
EARTH GND.
(SEE NOTE 1)
KEYPAD
(SEE NOTE 7)
FCC Registration Number AE398E-69554 AL-E Ringer Equivalence 0.0B
References: Hookup and Installation Instructions N9471 and Owner's Manual N9472
SYSTEM STABILIZATION MODE: Upon initial powerup of the system, all of the lights on the LED
keypad(s) will go ON and then go OFF for approximately 2 min. 10 secs and/or the LCD keypad(s) will
display STAND BY! for approximately 2 min. 10 secs. This occurs on a total powerup (if ARMED or
DISARMED in its prior state) or after a system reset. If the total system power is lost then upon power
restoral, the system will return to the previous arming state. The 2 min. 10 secs. interval is used to allow
motion detectors (interior zones) to stabilize on power up in order to prevent false alarms. THIS OPTION
CAN BE DISABLED BY MOMENTARILY (5 second minimum) PUTTING A JUMPER BETWEEN TERMINALS
13 AND 12.
System Wiring and Hookup
JP1
JP2
SYSTEM DEFAULT RESET JUMPERS
(300mA max for UL installations). Used for connection of devices rated
from 11.5 to 13.1VDC.
Power varies with transformer (SEE NOTE 2).
with the National Electrical code and ANSI/NFPA No. 74.
Under normal conditions this battery will last 3 years. Use only exact
replacements.
from the control unit with no barriers in between.
see Detail A. See manual for programming information.
Use model XL-2GTC trigger cable.
CONSTANT DC POWER (+)
AUX POWER
12VDC Reg., 500mA Max.
_
(SEE NOTE 2)
+
9
10
11
12
13
14
15
16
17
_
+
MODEL 368 CORD
TO RJ31X OR
CA31A JACK
SMOKE
DETECTOR
POWER
(9.5-12.2VDC,
50mA max)
HOME
TELCO
To re-load factory default values, remove all power
(AC & DC). Short JP1 to JP2. With short still applied,
re-apply power (AC then DC), wait 5 seconds, then
remove short with power still applied.
RED
BLACK
_
+
F2
10-15.5VDC
1 Amp
Aux. Power
(SEE NOTE 11)
Bell Power
3 Amps
F1
P1
18
19
20
21
22
_
+
-
+
BELL
-
+
SIREN
FIRE & BURGLARY
TRANSFORMER
ALARM OUTPUT
12VAC, 20VA
(11.5-13.1VDC,
(Connect to 24 HR.
1A max)
120VAC, 60 Hz Outlet
SEE NOTE 4)
S E C T I O N
CONTROL PANEL
POWER
12
1
MODEL ESL2048
EOL RELAY
12V, 4-6AH
BATTERY
MODEL 1240A
(SEE NOTE 6)
UL INSTALLATIONS REQUIRE LISTED
END-OF-LINE DEVICE. USE RESISTOR
F3
FROM EOL22 KIT. LOOK FOR LISTING
MARK ON ITEM.
Battery
4 Amps
WARNING:
THIS UNIT INCLUDES AN ALARM VERIFICATION
TRIGGER
FEATURE THAT WILL RESULT IN A DELAY OF THE
OUTPUTS
SYSTEM ALARM SIGNAL FROM THE INDICATED
CIRCUITS. THE TOTAL DELAY (CONTROL UNIT
(SEE NOTE 13)
PLUS SMOKE DETECTOR) SHALL NOT EXCEED
60 SECONDS. NO OTHER INITIATING DEVICES
SHALL BE CONNECTED TO THESE CIRCUITS
This fuse is
UNLESS APPROVED BY THE LOCAL AUTHORITY
NOT replaceable.
HAVING JURISDICTION.
(SEE NOTE 9)
CIRCUIT
CONTROL UNIT
(ZONE)
DELAY-SEC
_______
_____20______
PRODUCT COVERED UNDER
US PATENT #4,791,658
WARNING
: To prevent risk from
electrical shock, de-energize the system
control unit and disconnect the telephone
lines before servicing this unit.
LOAD NO.: 7
2
DETAIL A
SMOKE DETECTOR
9.5 - 12.2VDC
ZONE
13
LISTED
2
3
4
HOUSEHOLD
THERMOSTAT
ESL 104
UL LISTED
SMOKE
DETECTOR
MODEL
ESL445AT
2.2K EOL RESISTOR
SMOKE DETECTOR
MODEL DELAY-SEC
______ __________
2–1