Table of Contents

Advertisement

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING:
If the information in these
instructions is not followed exactly, a fi re or
explosion may result causing property damage,
personal injury or death.
FOR YOUR SAFETY
Installation and service must be performed
by a qualifi ed installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier call
the fi re department.
Do not store or use gasoline or other fl ammable
vapours and liquids in the vicinity of this or
any other appliance.
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
110712-72
TCWS.54CSTE
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL
TCWS54ST
SERIES C
POWER VENTED
SEE THRU FIREPLACE
TCWS.54CSTE
SERIAL #
5056.425218

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TCWS54ST and is the answer not in the manual?

Questions and answers

Summary of Contents for Town & Country Fireplaces TCWS54ST

  • Page 1 This appliance is not convertible for use with other gases, unless a certifi ed kit is used. MODEL This appliance is suitable for installation in a TCWS54ST bedroom or bed sitting room. SERIES C POWER VENTED SEE THRU FIREPLACE 110712-72 TCWS.54CSTE...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Table of Contents ................2 Table of Contents ................3 Certifi cations ................... 3 Caution ................... 4 Safety ..................... 4 Important Note for the Commonwealth of Massachusetts: ..... 5 Fireplace Dimensions ..............6 Minimum Clearances to Combustible Material ....... 6 Installation Requirements ...............
  • Page 3: Table Of Contents

    Table of Contents Wiring Diagram ................36 Vent Pipe Sealant ................. 37 Optional Tranquility Burner ............38 Propane Conversion ..............44 Optional Black Diamond Burner ........... 47 Gas Pressure Check ..............51 Burner Flame Adjustment ............. 52 Firebox Panels Installation ............53 Finishing Touch Trim Kit Instructions ..........
  • Page 4: Caution

    Caution FOR YOUR SAFETY - Do not install or operate your Town & Country fi replace without fi rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces Warranty and may prove hazardous.
  • Page 5: Important Note For The Commonwealth Of Massachusetts

    Important Note for the Commonwealth of Massachusetts: From Massachusetts Rules and Regulations 248 CMR 5.08: For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above fi nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfi ed.
  • Page 6: Fireplace Dimensions

    Fireplace Dimensions Fig. #1 70 3/4” 16 9/16” 35 5/8” 41 1/4” 19 7/8” 18” 10” 30 1/16” 53 3/4” Minimum Clearances to Combustible Material Fig. #2 NON-COMBUSTIBLE ZONE. COMBUSTIBLE FRAMING AND STEEL FRAMING DO NOT INSTALL ANY COMBUSTIBLE MATE- RIAL, ELECTRICAL WIRING OR GAS PLUMBING FINISH WALL ABOVE STANDOFFS IN THIS AREA.
  • Page 7: Installation Requirements

    Installation Requirements The Town & Country Fireplace installation and venting must conform to the local codes or, in the absence of local codes, current CSA B149.1 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 (in the USA). Only qualifi ed (licensed or trained) personnel should install this product.
  • Page 8: Standoffs

    Standoffs The framing kits, once assembled Fig. #6 and attached, are used as the top and side standoffs (see page 10 & 11.) HANDLE CONTROL Locating The Fireplace In planning the installation for the fi replace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed.
  • Page 9: Framing And Finishing

    Framing and Finishing Note: The fi replace should be in place A Steel Stud Framing Kit is supplied with the If the backer board is not to be fi nished with and venting installed before framing in fi replace and must be used unless the other non-combustible material such as tiles, or building an enclosure around the unit.
  • Page 10 Fig. #9 Fig. #9A IF FINISHING THE WALL ABOVE THE UNIT NON-COMBUSTIBLE BOARD DETAIL WITH PAINT, THE FRAMING KIT SHIPPED WITH THE UNIT SHOULD BE DISCARDED. USE FULL SHEETS OF CALCIUM SILICATE BOARD AND FULL LENGTH METAL STUDS TO FINISH AND FRAME AROUND THE UNIT. CALCIUM SILICATE BOARD IS A HIGH GRADE NON-COMBUSTIBLE MATERIAL WITH CEMENT, QUARTZ AND...
  • Page 11: Steel Stud Framing Kit

    Steel Stud Framing Kit TCWS.54STFRKIT Each Kit Contains: Item Part # Description Qty. 5049.9912 SCREW, WAFER #8 x 1/2 8493.4 STUD, SIDES 54” L 8493.2 STUD, OUTER SIDES 54” L 8493 STUD, UPPER/LOWER 38 1/16” L 8493.6 INNER CROSS BRACE 56 7/8”...
  • Page 12 NOTE: Sheet metal parts have sharp edges, use caution when handling. 1. Frame Assembly • Place 2 of #4 together as a top. • Place 1 of #6 into the joint with the long edge facing up. Align the 3 holes and screw together with wafer screw #1. •...
  • Page 13 2. Attach the Assembled Frame to the Fig. #13 Unit • Align the assembled frame to the unit framing brackets. (Fig #13) Attach at the fastening points through the access holes in the outer side studs (3). 3. Secure to Existing Framing •...
  • Page 14: Adjustable Lintel

    Adjustable Lintel Fig. #16 The adjustable lintel assembly has two orientations for desired fi nishing. The fl anged edge and the hemmed edge. The lintel comes factory installed with the fl ange edge out . If the desired edge is different from the factory setting, use the following steps to change it(Fig.#16).
  • Page 15: Maestro Control

    Fig. #16 Maestro Control Plumbing and Electrical The gas control system is located beneath the fi replace, below an access panel in the fi rebox bottom and the secondary fl oor (if installed). The fi replace is operated via a wall switch and a hand held remote control unit.
  • Page 16 Fig. #20 9. Route the communication cable as required to the wall control electrical box. 10. Attach the communication cable to the wall control. (Fig. #20) 11. Fasten the wall switch to the electrical box. 12. Fasten the faceplate to switch 13.
  • Page 17 Fig. #24 Pre-Purge Mode The TCWS.54CSTE is for use with a power vent only. Follow these instructions to activate the power vent pre-purge feature. This feature must be activated for the safe operation of this appliance. Switching to the power vent pre-purge mode: To turn feature ON and OFF, press and hold the STANDING PILOT button on the...
  • Page 18: Gas Supply

    Gas Supply Servicing of the appliance can be performed from inside the unit and through the access panel located in the fi rebox bottom. Caution: The gas line should be installed by a qualifi ed service person in accordance with all building codes.
  • Page 19: Venting

    Venting NOTE: This fi replace uses Power Vent only (TCVT.PVOB2, TCVT.PVOFM or TCVT. PVOFM3). Various combinations of vent runs may be used. For optimum performance and fl ame appearance, keep the vent length to a minimum and limit the number of elbows. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed with high temperature self adhesive tape.
  • Page 20: Tcvt.pvofm Power Vent Installation

    TCVT.PVOFM Power Vent Installation PAINT: Locate the fi replace as per the main instructions supplied. The vent terminal comes pre-painted Make the following modifi cations to add the components used with the Flush with Thurmalox 230 Series paint by Mount Power Vent Kits. This Kit can only be used in conjunction with the “C” series Dampney Co., but can be painted to match your wall fi nish color versions of Town and Country fi replaces, except the TC54.CE.
  • Page 21: Minimum Vent Length Chart

    Minimum Vent Length Chart Fig. #27 TCWS.54CSTE Minimum Pipe Rise Length 47” 1 foot Vent Terminal Minimum Clearances Fig. #28 INSIDE CORNER DETAIL FIXED CLOSED FIXED OPEN- CLOSED ABLE OPEN- ABLE AIR SUPPLY INLET AREA WHERE TERMINAL VENT TERMINAL GAS METER IS NOT PERMITTED A= clearances above grade, veranda, porch, deck, or balcony [* H= * not to be installed above a meter/regulator assembly within...
  • Page 22: Horizontal (Side Wall) Venting

    Horizontal (Side Wall) Venting This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe, Selkirk Direct-temp vent pipe or ICC Exceldirect vent pipe with a 5” inner pipe and an 8” outer pipe. For part numbers see the table of venting components on page 19 of this manual.
  • Page 23 7. For wall thicknesses greater than 7 1/2” and up to a maximum of Fig. #33 16 1/2” , attach the inner wall plate to the wall sleeve assembly, using the four screws provided.(Fig #32) Then slide this assembly over the terminal(Fig #33 &...
  • Page 24: Fan Wiring

    Fan Wiring The Flush Mount Power Vent assembly has an electrical connector block mounted internally. The external wiring from the main voltage/control module should be connected to this block. Follow the steps below to access this block. 1. Remove the 2 top and 2 bottom screws securing the end cap only.
  • Page 25: Terminal Dimensions

    Terminal Dimensions 13 1/4” 1 1/2” PAINT: 6 3/8” The vent terminal comes pre-painted with Thurmalox 230 Series paint by Dampney Co., but can be painted to 16 1/2” match your wall fi nish color using high temperature paint that can withstand temperatures of at least 250 degrees fahrenheit or 120 degrees 9”...
  • Page 26: Wiring Diagram

    Wiring Diagram TCWS.54CSTE 110712-72...
  • Page 27: Tcvt.pvofm3 Power Vent Installation

    TCVT.PVOFM3 Power Vent Installation PAINT: Locate the fi replace as per the main instructions supplied. The vent terminal comes pre-painted Make the following modifi cations to add the components used with the Flush with Thurmalox 230 Series paint by Mount Power Vent Kits. This Kit can only be used in conjunction with the “C” series Dampney Co., but can be painted to match your wall fi nish color versions of Town and Country fi replaces, except the TC54.CE2.
  • Page 28: Terminal Dimensions

    Horizontal (Side Wall) Venting This kit uses either Simpson Duravent GS direct vent pipe, Secure Vent direct vent pipe, Selkirk Direct-temp vent pipe or ICC Exceldirect vent pipe with a 5” inner pipe and an 8” outer pipe. For part numbers see the table of venting components on page 19 of this manual.
  • Page 29 7. For wall thicknesses greater than 7 1/2” and up to a maximum of Fig. #43 16 1/2” , attach the inner wall plate to the wall sleeve assembly, using the four screws provided.(Fig #42) Then slide this assembly over the terminal(Fig #43 &...
  • Page 30: Fan Wiring

    Fan Wiring The Flush Mount Power Vent assembly has an electrical connector block mounted internally. The external wiring from the main voltage/control module should be connected to this block. Follow the steps below to access this block. 1. Remove the 2 top and 2 bottom screws securing the end cap only.
  • Page 31: Wiring Diagram

    Wiring Diagram TCWS.54CSTE 110712-72...
  • Page 32: Tcvt.pvob2 Power Vent Installation

    TCVT.PVOB2 Power Vent Installation Locate the fi replace as per the main instructions supplied. Make the following modifi cations to add the components used with the Power Vent kits. This kit can only be used in conjunction with the “B” & “C” series versions of Town and Country Fireplaces.
  • Page 33: Horizontal (Side Wall) Venting

    Horizontal (Side Wall) Venting Wall Thimble (Not Supplied) 1. Locate the power vent termination following the clearance to combustible table, venting confi guration diagram (Fig. #51), and terminal location diagram (Fig. #28). 2. Cut and frame an 11” x 11” opening. The centre of the square hole should line up with the centre line of the horizontal pipe.
  • Page 34: Vertical (Through Roof) Venting

    Vertical (Through Roof) Venting VENT PIPE This kit uses either Simpson Vertical installations must use the optional TCVT.PVVCA vertical adaptor box in Duravent GS direct vent pipe, conjunction with this kit. The vertical adaptor box can only be installed on a fl at surface. Secure Vent direct vent pipe, Sloped surfaces require the construction of a chase which provides the minimum interior, Selkirk Direct-temp vent pipe or...
  • Page 35: Vertical (Through Roof) Venting

    Vertical (Through Roof) Venting Fig. #53 Part F Vertical Rain Cap TCVT.8074 MUST ALIGN #8 x 1/2" S.S. (16 Required) Power Vent TCVT.PVOB2 NOTE: Holes to secure rain cap are not predrilled Part D Junction Box Cover Part E Exhaust Shield - DISCARD - Part C Drip Shield...
  • Page 36: Wiring Diagram

    Wiring Diagram TCWS.54CSTE 110712-72...
  • Page 37: Vent Pipe Sealant

    Vent Pipe Sealant Fig. #54 APPROVED “HIGH TEMP.” VENT PIPE SELF-ADHESIVE TAPE (SUPPLIED) All outer joints of the vent pipe must be sealed with the approved "High Temperature" self- adhesive aluminium tape provided. Wrap the tape completely around the joint and press fi rmly in place.
  • Page 38: Optional Tranquility Burner

    Optional Tranquility Burner Contents of Package: 3.4 LBS SAND HARDWARE PACK PILOT ROCK BURNER ASSEMBLIES BURNER TRAY ASSEMBLY PEBBLE SETS SECONDARY FLOOR HALVES WITHOUT LIGHTS TRAY LEGS TCWS.54CSTE 110712-72...
  • Page 39 Installation: ATTACH HERE AND ON OPPOSITE SIDE If converting to propane see conversion in- Fig #55 structions on page #44 before proceeding. Install one side of the secondary fl oor as shown. Repeat with the other side but do not put in the two center screws until you put the center tray leg in place (Fig.
  • Page 40 Fig #58 NOTE: check air shutter for correct fuel setting before proceeding further. Both burners are the same. Fully closed for natural gas. 13/64 (0.2)” open for LP. Install burners as shown in Fig. #58. Be sure to engage the venturis onto the orifi ces in the manifold and rest burners together on the center tray leg.
  • Page 41 Fig #61 Install burner tray as shown in Fig. #61 using 8 screws. Secure tray around pilot fi rst then the other 6 screws. SECURE PILOT HERE FIRST Fig #62 Place sand into the burner tray and brush smooth. Use caution not to get sand near the burner ports (Fig.
  • Page 42 Each rock has a slot in it’s base and Fig #67 Fig #63 is marked with a letter and an arrow. (Fig. #63) Place each rock as per the following Fig #64 Fig #68 photographs, start from the right hand side of the burner and ensure that the arrow on each rock points towards the same side of the fi replace (Fig.
  • Page 43 Fig #73 Fig #71 11. Place the fi fth set of rocks randomly around the burners in the sand as desired. 12. Place the pilot rock over the pilot with the opening facing the center of the burner . Fig #72 Fig #74 Fig.
  • Page 44: Propane Conversion

    MINIMUM RATE SCREW (5005.16) convert as follows using the compo- Kit # TCWS.54STLP for use with model: Pour utilise avec du modèle: nents supplied with the burner: TCWS54ST Date: ______________________ By / Par: ___________________ This appliance was converted LP GAS/...
  • Page 45 6. Slide the pilot adjustment band over and Fig #83 Fig #84 ensure that the hole in the orifi ce band is showing. Fig. #83 shows NG position Fig. #84 shows LP position. LP POSITION NG POSITION Fig #85 Fig #18 Remove the secondary fl oor on the control compartment side and remove the access panel, 9 screws, and set...
  • Page 46 13. Check all connections for leaks. ADD DATE Fig #90 ADD NAME Kit # TCWS.54STLP for use with model: Pour utilise avec du modèle: TCWS54ST Date: ______________________ By / Par: ___________________ This appliance was converted LP GAS/ to PROPANE GAS with...
  • Page 47: Optional Black Diamond Burner

    Optional Black Diamond Burner Contents of Package: IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be kept together. Refer to the Installation and Operating Instructions for proper gas supply, safety requirements and operating instructions.
  • Page 48 Installation: If conver ting to propane see Fig #91 PILOT HOLE conversion instructions on page #43 before proceeding. Install the secondary fl oor on the side away from the gas connections fi rst. 2. Insert the wires leading from the secondary fl oor half through one of the grommets in the bulkhead plate.
  • Page 49 Remove the panel retainer clips from Fig #94 both sides of the upper fi rebox(Fig. #94). PANEL RETAINER CLIP. Fig #95 Insert both side panels. (Fig. #95) NOTE: PROCEED TO AND FOLLOW IN- STRUCTIONS IN “GAS PRESSURE CHECK” SECTION ON PAGE 51 BEFORE INSTALLING BURNER TRAY AND MEDIA.
  • Page 50 11. Place the two porcelain strips, supplied Fig #97 with the panel set, into the fi replace as shown in Fig. #97 with the narrow edge facing the center of the fi replace. 12. Spread the glass media evenly over the entire mesh tray, leaving the small protrusion above the pilot clear of glass.
  • Page 51: Gas Pressure Check

    Gas Pressure Check Note: To test the gas pressure, turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port. Verify gas pressures with the fi replace lit and on the highest setting. Fig #99 If installed, remove all media and the burner tray.
  • Page 52: Burner Flame Adjustment

    Burner Flame Adjustment The air shutter on the burner tube controls the primary combustion air. It is set to the closed position at the factory for natural gas fuel. For LP see Pg.44. Some adjustment may be nec- essary to obtain desired fl ame and to eliminate carbon deposits. Evaluate fl ame appearance after the fi replace has reached operating temperature.
  • Page 53: Firebox Panels Installation

    Fig. #102 Firebox Panels Installation RETAINING CLIP Remove side panel securing tabs for both sides in upper fi rebox. (Fig. #102) Fig. #103 Place bottom of side panel in fi rst then tip up into vertical position (Fig. #103). Attach the side panel securing tabs previously removed. Repeat steps 2 & 3 Fig.
  • Page 54: Finishing Touch Trim Kit Instructions

    Finishing Touch Trim Kit Instructions Place two smaller magnets on back of each side rail. Place two larger magnets on back of the top and bottom rails. Attach the side rails. Even the ends up with the door frame. Attach the top and bottom rails and adjust so mitres are even at the corners. Place TC magnetic logo in bottom right corner.
  • Page 55: Lighting Instructions

    Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil. 180612 5051.175 5-TCWS54ST First Fire When lit for the fi rst time, the fi replace will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process.
  • Page 56: Maestro Control System

    Maestro Control System Remote Control Initial Setup Fig. #106 This fi replace is supplied with a wall control Fig. #107 and hand held remote control. Please note only genuine Town & Country Fireplace wall controls and hand held remote controls can be used on this fi replace.
  • Page 57: Maestro Control System - Operation

    Fig. #109 Childproof Lock An additional feature of this remote control is the childproof lock. To activate this system press and hold the timer and thermostat buttons for approx. 5 seconds until the “lock” symbol ap- pears on the remote display. (Fig. #109) The remote control hand set buttons are now locked and the lock symbol will reappear every time a button is pressed on the remote control until the timer and thermostat buttons are pressed and held again.
  • Page 58 Fig. #111 Program Mode Fig. #113 (To preset up to two on and off periods per day) The program mode has two settings for weekdays and two for weekends. The hand held remote comes with the following pre programmed settings: Weekday Program (Monday through Friday) Program one (P1) turns ON at 7:00am and...
  • Page 59 Fig. #115 Thermostatic Mode Fig. #117 THERMOSTATIC MODE THERMOSTATIC BUTTON (Only for use where permitted) BUTTON (Operates the fi replace within a set tem- perature range) The fi replace is shipped with thermostatic mode function deactivated. If this function is permitted for use in your area it can be acti- vated by depressing the recessed button on the back of the hand held remote.
  • Page 60: Maintenance

    APPENDIX Maintenance CAUTION: Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fi replace and its venting should be inspected at least once a year by a qualifi ed service person. Glass Panel: Warning: Do not operate fi replace with glass panel removed, cracked or broken.
  • Page 61: Replacement Parts - Tcws.54Cste

    Replacement Parts - TCWS.54CSTE (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. TCWS BODY ASSEMBLY ......TCWS.54CSTE FINISHING TOUCH TRIM KIT..TCRP.54WSTRIMKIT GLASS ASSEMBLY (c/w gasket) ..GLAS.2062ASSY ORIFICE (2pcs) ........5021.332A FRAMING KIT........TCWS.54STFRKIT MAIN GAS SUPPLY TUBE (1pcs) ..5019.223 PANEL SETS BLACK PORCELAIN ......TCPN.54STBK BROWN PORCELAIN .......TCPN.54STCB...
  • Page 62: Replacement Parts - Tranquility Burner

    Replacement Parts - Tranquility Burner (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..DESCRIPTION ..........PART NO. #1..TRANQUILITY BURNER KIT..TCWS.54NGST04C #2..PEBBLE ASSEMBLY(5 boxes)..5096.921 #3..SAND (Two Bags) ......TC42.SAND34 #4..PILOT ROCK, BLACK........8421-A ....PILOT ROCK, GREY ........8422-A NOT SHOWN KIT CONTENTS: TCWS.54CSTE 110712-72...
  • Page 63: Replacement Parts - Black Diamond Burner

    Replacement Parts - Black Diamond Burner (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..DESCRIPTION ............PART NO. #1..BLACK DIAMOND BURNER ..TCWS.54NGST03C #2..GLASS MEDIA (3 required) ....TCRP.501201 #3..LIGHT BULB ..........5033.713 NOT SHOWN KIT CONTENTS: TCWS.54CSTE 110712-72...
  • Page 64: Replacement Parts - Tcvt.pvofm

    Replacement Parts - TCVT.PVOFM ITEM PART No. DESCRIPTION TCVT.8018 FLUSH MOUNT POWER VENT ASSY. 8016 BLOWER END CAP 8018 DECORATIVE COVER 8020 INNER WALL PLATE 5068.8065 1/4” LDF PAPER GASKET TCVT.8016 TCVT.FMPV OUTER CASING ASSEMBLY 5024.62 BLOWER, POWERVENT TCVT.8028 WALL SLEEVE ASSEMBLY 8029 WALL PIPE COVER * NOT SHOWN...
  • Page 65: Replacement Parts - Tcvt.pvofm3

    Replacement Parts - TCVT.PVOFM3 ITEM PART No. DESCRIPTION TCVT.8043 FLUSH MOUNT POWER VENT ASSY. 8043 BLOWER GRILL 8043.5 GRILL COVER 8020.5 INNER WALL PLATE 5068.8065 1/4” LDF PAPER GASKET TCVT.8035 TCVT.FMPV OUTER CASING ASSEMBLY 5024.63 BLOWER, POWERVENT TCVT.80285WLD WALL SLEEVE ASSEMBLY 8029 WALL PIPE COVER * NOT SHOWN...
  • Page 66: Replacement Parts - Tcvt.pvob2

    Replacement Parts - TCVT.PVOB2 ITEM PART No. DESCRIPTION ITEM PART No. DESCRIPTION 5024.62 BLOWER POWER VENT INSIDE COVER 5027.15 PRESSURE SWITCH EXHAUST SHIELD 3/8” STRAIN RELIEF SECONDARY RAIN SHIELD #8 x 1/2” PAN HD SKT 18.8 STAINLESS STEEL JUNCTION BOX ID x .379 OD x .062 THK TOP COVER 1/4 MED LOCKWASHER 18.8 SS...
  • Page 67: Replacement Parts - Maestro Control System

    Replacement Parts – Maestro Control System (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..DESCRIPTION ..........PART NO. ITEM ..DESCRIPTION ..........PART NO. #1..CONTROL ASSEMBLY KIT ....TCRP.8470 #5..COMMUNICATION CABLE KIT ..5005.06 #2..BULKHEAD ASSEMBLY KIT ....TCRP.8485 #6..
  • Page 68: Wiring Diagram

    Wiring Diagram Fig. #120 TCWS.54CSTE 110712-72...
  • Page 69: Light Wiring Diagrams

    Light Wiring Diagrams Fig. #121 UPPER LIGHTS MEDIA TRAY LIGHTS (Optional) GREEN GREEN TERMINAL TERMINAL BLOCK BLOCK (FLOOR LIGHTS) (UPPER LIGHTS) GROUND GROUND WALL WALL SWITCH SWITCH TCWS.54CSTE 110712-72...
  • Page 70 TCWS.54CSTE 110712-72...
  • Page 71: Safety Label Location

    Maximum supply pressure / Pression maximum d’alimentation: 13.9 in/wc / 13.9 po/c.e. 13.9 in/wc / 13.9 po/c.e. MODEL/ (3.45 kPa) (3.45 kPa) TCWS54ST MODELE: Manifold pressure / Pression de la tuyauterie: Maximum 3.5 in/wc / 3.5 po/c.e. 11.0 in/wc / 11.0 po/c.e.
  • Page 72 Technical support: 1-250-748-1184 Web site: www.townandcountryfi replaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada...

Table of Contents