1) The Double Knock Suite defines the zones that will be assigned a double
knock attribute.
2) A zone should be assigned a double knock attribute when maximum false
alarm protection is required. A zone with a double knock attribute must be
activated either twice within 10 seconds or once for longer than 10 seconds
in order to cause an alarm.
3) Double knock is not recommended for Entry/Exit zones.
4) Double knock will not operate with Push to Set or Keyswitch zones.
5) Double knock should NOT be used for Fire, Panic, or Tamper zones.
3.15.4

Programming the Manual Omit Suite

The Manual Omit Suite defines the zones that may be manually omitted by the
user. To program the Manual Omit Suite, enter
currently included in the Manual Omit Suite will illuminate. Press the appropriate
numbered button(s) of the zone(s) to be included or excluded. Press
The system will chime to confirm that the new Manual Omit Suite has been
accepted. The system will then automatically revert to the Programming Menu and
all the zone lights will illuminate.
1) To prevent the user from omitting 24 Hour zones (Fire, PA and Tamper)
these would be excluded from the Manual Omit Suite.
2) Zones not included in the Manual Omit Suite will still be omitted if they are
excluded in the Part Set Suites.
3.15.5

Programming the Zone Disable Suite

The Zone Disable Suite defines the zones that are not monitored. Disabled zones
cannot cause alarm. A zone could be disabled:
! if it was not used,
! while waiting for a faulty detector to be replaced.
To program the Zone Disable Suite, enter
currently included in the Zone Disable Suite will illuminate. Press the appropriate
numbered button(s) of the zone(s) to be included or excluded. Press
The system will chime to confirm that the new Zone Disable Suite has been
accepted. The system will then automatically revert to the Programming Menu and
all the zone lights will illuminate.
If a zone is disabled in this suite it will be necessary to enter the suite again to
re-enable it.
3.15.6

Programming the Zone Soak Test Suite

Soak Test is used to prevent false alarms for a set period after a new
installation or when a detector has been replaced. If a zone on Soak Test
activates it will not cause alarm but it will still be logged. Afterwards the zone
will have a standing fault and will need to be omitted before the system can be
set. After the Soak Test Time (section 3.13, page 33) zones that have not
activated will be automatically removed from the Soak Test Suite.
36
&*
&*
. The zone lights of the zones
%*
. The zone lights of the zones
%*
%(
.
,
,
.
INS 034-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Veritas 8compactVeritas r8

Table of Contents