Texecom Premier 8SP User Manual

Texecom Premier 8SP User Manual

Security control panel
Hide thumbs Also See for Premier 8SP:

Advertisement

THANK YOU FOR VOTING TEXECOM
MASTER USER MANUAL
Security Control Panel
Issue 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Premier 8SP and is the answer not in the manual?

Questions and answers

Summary of Contents for Texecom Premier 8SP

  • Page 1 THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL Security Control Panel Issue 1...
  • Page 2: Table Of Contents

    Contents Premier 8SP Master User Manual Contents About the Alarm System ......3 Fire Safety & Maintenance .......19 Introduction ..............3 Fire Safety ...............19 About this Manual............3 Fire Alarm Operation ............19 Fire Detection..............3 Household Fire Safety Audit ..........19 Monitoring ................
  • Page 3: About The Alarm System

    Premier RKP8 SP: The Premier RKP8 SP is the standard This manual is a thorough explanation of all system remote keypad for the Premier 8SP control panel. This functions, including troubleshooting and programming remote keypad has 8 zone indicator lights and four status Access codes in addition to performing basic system lights (Alarm, Service, Armed and Ready).
  • Page 4: Keypad Layouts

    About the Alarm System Premier 8SP Master User Manual Keypad Layouts Alarm Light: If an alarm has occurred whilst the system is armed the Alarm light will illuminate. The alarm system cannot be Armed until a standing Alarm has been acknowledged/reset (see “Acknowledging an Zones Alarm”...
  • Page 5: Function Keys

    Premier 8SP Master User Manual About the Alarm System Function Keys The remote keypad function keys are described as follows: Function The Bypass key is used for either group or manual bypass of zones (see page 8). The Menu key is used to access the more advanced user functions and programming options.
  • Page 6: Operating The Alarm System

    Operating the Alarm System Premier 8SP Master User Manual 2. Operating the Alarm System " To Away arm the alarm system proceed as follows: Introduction Enter Access code Before attempting to operate the alarm system ensure you have familiarised yourself with all the arming and disarming...
  • Page 7: Cancelling The Arming Process

    Premier 8SP Master User Manual Operating the Alarm System Cancelling the Arming Process Auto Stay Arming If your installer has enabled the Auto Stay feature the system " To cancel the arming process during the exit delay: will automatically Stay arm if the entry/exit zone (front door) is not activated whilst attempting to Away arm the system.
  • Page 8: Bypassing Zones

    Operating the Alarm System Premier 8SP Master User Manual Group Bypass Bypassing Zones The Group Bypass feature allows you to Bypass a predefined group of zones. The alarm system has up to four Manually Bypassing Zones groups. Bypassing a zone prevents it from causing an alarm.
  • Page 9: Quick Bypass And Arm

    Premier 8SP Master User Manual Operating the Alarm System Quick Bypass and Arm The Quick Bypass and Arm feature allows you to Bypass a predefined group of zones and Away or Stay arm the system. The alarm system has up to four groups.
  • Page 10: User Functions Menu

    User Functions Menu Premier 8SP Master User Manual 3. User Functions Menu This section covers the more advanced functions that Service Faults selected users can perform with the alarm system. The following functions are available: The response to a Service Fault condition is programmed by the installer but is normally limited to the keypad buzzer.
  • Page 11: Anti-Code Reset

    Premier 8SP Master User Manual User Functions Menu Anti-code Reset Service Faults Displayed on LED Keypads Light Fault Condition This feature is normally used in the UK where users are not AC Fail permitted to reset the panel following a communicated alarm.
  • Page 12: Change User Code

    User Functions Menu Premier 8SP Master User Manual Change User Code Abort Communications All users of the alarm system can change their own Access This option aborts any communications to the Alarm code number. Receiving Centre. " To change your Access code, proceed as follows: "...
  • Page 13: System Program Menus

    Premier 8SP Master User Manual System Program Menus 4. System Program Menus The Master User and Users with the relevant access level A programming menu is selected by entering a two-digit can access the System Program Menus. These menus allow menu code.
  • Page 14: Programming Users

    System Program Menus Premier 8SP Master User Manual Programming Users Enter Access code Then press then Led Key Slow Flash Zones Armed Fast Flash Alarm Service Ready Program User Enter User Number Zones Zones Armed Armed Alarm Alarm Service Ready...
  • Page 15: Program User

    Premier 8SP Master User Manual System Program Menus From Previous Page Program Manager Users Enter User Number Zones Zones Armed Armed Alarm Alarm Service Ready Service Ready Enter Code Press if code is less than 6 digits. Zones Alarm Armed...
  • Page 16: User Options

    System Program Menus Premier 8SP Master User Manual User Options User Options can be enabled or disabled for a selected user so that the level of access to the system may be altered. The following options are available: #, Allow Arming On: The user can arm the system.
  • Page 17: System Tests & Utilities

    Premier 8SP Master User Manual System Program Menus System Tests & Utilities Enter Access code Then press then Led Key Slow Flash Zones Armed Fast Flash Alarm Service Ready Walk Test Top line scrolls active zones Bottom line scrolls tested zones...
  • Page 18: Walk Test

    System Program Menus Premier 8SP Master User Manual From Previous Page Banner Text (LCD Only) Text Editing Keys Press to edit text. . , ? ! 1 @ ” - & a b c 2 A B C d e f 3 D E F Use keys to enter/edit text.
  • Page 19: Fire Safety & Maintenance

    Premier 8SP Master User Manual Fire Safety & Maintenance 5. Fire Safety & Maintenance Fire Escape Planning Fire Safety There is often very little time between the detection of a fire and the time it becomes deadly. It is therefore very important Fire Alarm Operation that a family escape plan be developed and rehearsed.
  • Page 20: Maintenance

    Fire Safety & Maintenance Premier 8SP Master User Manual • We recommend that you contact your local fire Glossary department and request further information on fire safety and escape planning. If available, have your Glossary of terms used in this manual: local fire prevention officer conduct an in-house fire safety inspection.
  • Page 21: Installation Records

    Premier 8SP Master User Manual Installation Records 6. Installation Records Control Panel Location: Keypads Fire Police Medical Quick Keypad Location Model Silent Keys (1 & 3) (4 & 6) (7 & 9) Timers Timer Value Timer Value Exit Time: Sec.
  • Page 22: Users

    Installation Records Premier 8SP Master User Manual Users User Name Type Disarm Bypass Open/Close Engineer Master User Installer Details Installation Company: _________________________________________________________________________________ Address: _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ Telephone: _________________________________________________________________________________ Fax: _________________________________________________________________________________ Email: _________________________________________________________________________________ Alarm Receiving Centre: ________________________________________________________________________________ Account No: _________________________________________________________________________________...
  • Page 23: Notes

    Premier 8SP Master User Manual Installation Records Notes INS237...
  • Page 24 © Texecom Ltd. 2003 Premier Endstation and Keypads are protected by UK and International Registered Design. Registered Design Numbers: 2041830, 2047440 and 2089016 INS237...

Table of Contents

Save PDF