Heartway Medical Products S12 User Manual page 30

Hide thumbs Also See for S12:
Table of Contents

Advertisement

5
Brake fault
6
Out of Neutral
at Power Up
7
Speed
Error
8
Motor
Error
9
Other Internal
Errors
Note:
If you experience any technical problems, it is recommended that you check with your
local dealer before attempting to troubleshoot on your own.
The following symptoms could indicate a serious problem with your power scooter.
Contact your local dealer if any of the following arises:
1. Motor noise
2. Frayed harnesses
3. Cracked or broken connectors
4. Uneven wear on any of tires
5. Jerky motion
6. Pulling to one side
7. Bent or broken wheel assemblies
8. Does not power up
9. Powers up, but does not move
Drive
inhibited
Drive
inhibited
Pot
Drive
inhibited
Volts
Drive
inhibited
Drive
inhibited
for a few minutes, and then turn the power back on
again.
The controller has detected a shorted motor. Check
the loom for shorts and check the motor. Contact
your service agent.
Check that the park brake release lever is in the
engaged position .
The park brake coil or wiring is faulty. Check the park
brake and wiring for open or short circuits. Contact
your service agent.
Throttle is not in neutral position when tuning switch
key on. Return throttle to neutral, turn power off and
back on again. Throttle may need to be re-calibrated
Check throttle wiring.
The throttle or its wiring is faulty. Check for open or
short circuits.
Throttle may not be correctly set up. Contact your
service agent.
The motor or its wiring is faulty. Check for open or
short circuits.
Contact your service agent.
Contact your service agent.
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents