Start-Up Instructions; Shut-Down Instructions - L.B. White Jet 200 Owner's Manual And Instructions

Circulating construction heater
Table of Contents

Advertisement

Burn H H azard
Close the manual main burner valve before lighting the
pilot.
Failure to do so will result in the main burner igniting
when the pilot is being lit.
Serious injury or death by burns may occur.
1.
Slowly open the LP Gas supply container valve.
2.
Fully depress the button on the pilot safety control
valve while applying flame to the pilot.
FIG. 13
1. Close the gas supply valve located on the LP gas
supply container.
2. Allow the heater to burn off any fuel gas remaining in
the gas supply line.
3. Close the manual main burner valve on the heater.
WARNING
MANUAL MAIN
BURNER VALVE
PILOT
BUTTON

Start-Up Instructions

ATTENTION
On new installations it may take a short time for gas to
purge out any air in the pilot line before the pilot stays
lit.
3.
Keep the pilot button depressed for about 30
seconds to allow the thermocouple to warm up so the
pilot stays lit after the pilot button is released.
4.
Connect the heater's power cord to an approved
electrical supply.
5.
To ignite the main burner:
Models 324 and 328
- Fully open the manual main burner valve located
between the pilot safety control and burner.
- The main burner will light.
Models 326 and 330
- Fully open the manual main burner valve located
between electrical solenoid valve and burner.
- Set the thermostat on the control panel to a point
above room temperature
- The main burner will light.

Shut-Down Instructions

4. For heaters so equipped, set the thermostat to "Off"
or "No Heat".
5. Disconnect the heater from its gas and electrical
supplies.
11