BASE SENSOR TEST

This test is used to determine if the sensors located inside the printer are working correctly.
To run the Base Sensor Test:
1.
Select BASE SENSOR TEST from DIAGNOSTICS.
2.
Select one of the test categories:
Cover and Door
Devices
Exit level
Media Path
3.
Select the actual test to perform.
Each of the tests categories includes the individual sensors that can be manually actuated, and the display
shows Open or Closed.
Cover and Door
Door A left side
Door B left/lower
Door C 2TM/TTM
Door D duplex left
Door E exit2 left
Door J front
Door K hcf top
Devices
PC unit present
Exit2 present
Exit level
Std bin full exit1
Std bin full exit2
Media Path
Registration
Fuser exit
Exit1 shift hp
Exit2
Exit2 shift hp
Manually actuate the sensors to verify that each sensor switches from Open to Closed.
Press Back (
) or Stop (
) to exit the test.
) or Stop (
) to exit the test.