System Connections - Maytag Washer/Dryer Installation Instructions Manual

Stacked washer/dryer
Hide thumbs Also See for Washer/Dryer:
Table of Contents

Advertisement

12,
For electric dryers:
I
TO MAKE ELECTRICALCONNECTIONFOR U.S. DRYERS
Reviewelectrical requirements on page 6 of these instructions.
IMPORTANT- All U.S. models are produced for a 3-WIRE SYSTEM
/®l _er_
CONNECTION. The dryer frame is grounded to the neutral conductor
at the terminal block. A 4-WIRE SYSTEMCONNECTIONis required
for new or remodeledconstruction,mobile homes, or if local codes do
not permit groundingthrough neutral. If the 4-wire system is used,
_ _
|
the dryer frame cannot be grounded to the neutral conductor at the
/
O
terminal block. Refer to the following instructionsfor 3- and 4-WIRE
,Figure 25
SYSTEM CONNECTIONS.
Removethe terminal block cover plate. (See figure 25.)
I
i
B
I
A protective conduit (plastic)is providedfor the power cord. Cut the
conduit so that it is approximately18 inches shorterthan the power
cord and thread the power cord through the conduit. (See figures26 &
27.)
Insert the power cord with a U.L. listed strain relief through the hole
Figure 26
provided in the cabinet near the terminal block. Note, a strain relief
must be used.
3-WIRE SYSTEM CONNECTIONS
Do not loosenthe nuts already installed on the terminal block. Be
sure they are tight. Use a 3/8 inch deep nut driver.
If the power cord has terminals, place the terminals over the existing
nuts on the posts. The neutral (white or center wire on power cord)
Figure27
conductormust always be connected to the center (silver colored)
post of the terminal block.
3-Wire System with
Secure in place using the nuts provided in the parts oackage. If the
,__,,_Power
Cord Attached
power cord does not have terminals, use the cupped washers ahead
of the nuts.
Ground
Be sure the terminal block nuts are tight. Secure the power cord in
position. Tighten the strain relief screw(s) in order to clamp the strain
relief to the cord. (See figure 28.)
Replacethe terminal block cover.
Neutral
BEFOREOPERATINGOR TESTING, follow the grounding directions
on page 5.
Strain
4-WIRE SYSTEM CONNECTIONS
relief
Removethe ground strap screw from the terminal block support. Fold
Figure 28
the ground strap over so both ends of the ground strap are attached
to the center terminal block post.
4-Wire System with
Connectthe neutral (white)conductor of the cord to the center (silver)
Power Supply Attached
post of the terminal block. Connectthe grounding (green) wire of the
cord to the terminal block support using the ground strap screw.
--
°
Folded
Connectthe red and black wires of the cord to the outer posts of the
Neutral
_
_.'_'_
Ground
terminal block.
Post ----. __/
Strap
Be sure the terminal block nuts are on tight. Secure the power cord in
positiOn.relief
to theTightencord,
the(seeStrainfigurerelief29.)screw(s)
in order to clamp the strain
•///__
/e Neutral
Replacethe terminal block cover.
Strain
WARNING: If converting from 4-wire electrical systems to 3-wire, the
o _
Relief
ground strap must be reconnectedto terminal block support to ground
(_
4''/
the dryer frame to the neutral conductor.
Figure 29
Page 15