Operation
3g. Operating the pump - Time out
The "time out" feature that will allow the user to temporarily stop the pump for maintenance work without disrupting the 24 hour
schedule (i.e., for backwashing the filter). If the pump is currently running, the user can press and hold the START button for more than
three (3) seconds and the pump will stop and remain off until the user presses and holds the START button again for more than three
(3) seconds. The START and OVERRIDE buttons will blink once every second indicating that the "time out" feature is enabled. These
LEDs will stop blinking once this feature is cancelled.
TEMPORARY STOP WITH AUTOMATION CONTROL SYSTEM INPUT
Temporary stop functionality only works while the pump is being controlled by an automation input. If the
motor is being controlled by the integrated key pad and STOP is pressed, the motor will stop and remain
stopped.
The pump has a "temporary stop" feature that will immediately stop the pump when being controlled by an automation input. The user
can press the STOP button while the pump is running and the pump will stop and stay off for four (4) minutes. Once this time has
elapsed, the pump will return to normal operation and accept an input from an automation input source.
Note: If the pump is operating from automation input, the '0 RPM' LED of the bar graph will blink once every second indicating the
"temporary stop" feature has been activated. After the specified time period, the pump will return to normal operation and accept an
input from any automation input source. Refer to page 14 for additional details on automation control system inputs.
3h. Operating the pump - Reset factory defaults
The eviroMAX user interface has a "Reset to Factory Defaults" feature to restore the schedule settings back to the original values
programmed at the factory. The user must press and hold the STOP and OVERRIDE buttons for three (3) seconds to reset the settings
back to factory defaults. All of the UI bar graph LED's will flash three (3) times to confirm the settings were restored to factory defaults.