Operating The Pump - Speed Selection; Operating The Pump - Variable Speed Adjustment - STA-RITE enviroMAX Owner's Manual

Variable speed pool pump
Table of Contents

Advertisement

Operation
3a. Operating the pump - Speed selection
The Sta-rite enviroFLO comes pre-programmed with the following default speeds:
Start/Stop buttons
Press Start to turn start pump. Press Stop to stop pump.
If power is removed, motor will return to STEP1.
Motor will remember ON/OFF state.
3b. Operating the pump - Variable Speed Adjustment
If the default speed settings do not perfectly match the particular installation, they can be adjusted as follows:
(To ensure the pump performs according to the energy rating label it is recommended to use the default low speed
setting of 1600RPM, for pool filtering).
1.
or
2.
Note: If power is cycled to the pump and the
user does not press the STOP key, the pump
will automatically start and run the
programmed default schedule shown in the
chart above. This feature ensures that the
pump will re-start in the event of a
power outage. The pump will start on STEP 1.
enviroMAX
Press for high speed
2600RPM
Operating some
water features such
as jets or waterfalls.
Solar heating
Manual vacuum
or
Note: The pump must be Stopped (Press STOP
Key) when programming the DURATION and
SPEED of the STEP 1, STEP 2, and STEP 3
keys. OVERRIDE DURATION and SPEED can
be programmed when the pump is either
stopped or running.
1
1
0
0
Press for medium speed
2100RPM
Cleaning with an
automatic suction
cleaner
Speed / Application
Press Stop, then the Step# button, corresponding to the speed you
wish to change. Firstly the LED above duration is lit (you can press
+,- buttons to change duraton in 2 hour segments). Press again so
that the LED above "SPEED" is lit.
Press '-' to decrease speed by one level with 600rpm as the
minimum limit.
Press '+' to increase speed by one level with 3450rpm as the
maximum limit.
The speed setting will be automatically saved.
Note: The pump can only be set to operate on a
24-hour schedule. If a user attempts to
program a schedule with a combined duration
for all three steps greater than 24 hours, the
pump software will retain the current STEP
time duration only, and will zero out the other
two STEP time settings. As an example, if STEP
1 equals eight (8) hours, STEP 2 equals nine (9)
hours, and STEP 3 equals eight (8) hours – for
a combined 25 hours – the pump will retain the
setting for the current Step being programed
and zero out the remaining two.
Press for low speed
Override
1600RPM
3100RPM
Filtration and
Backwashing
water circulation
filter.
10

Advertisement

Table of Contents
loading

Table of Contents