60 cycle “c” and “cc” series centrifugal pumps for swimming pool use (16 pages)
Summary of Contents for STA-RITE JSAL15D-06
Page 1
This manual should be furnished to the end user of this system; its use will reduce service calls and chance of injury and will lengthen system life. Sta-Rite Pool/Spa Group 293 Wright Street, Delavan, WI 53115 North America: 800-752-0183, FAX 800-582-2217 International: 414-728-5551, FAX: 414-728-4461, TELEX: ITT 4970245 Union City, TN •...
HIGH-RATE SAND FILTER SYSTEM To avoid unneeded service calls, prevent possible injuries, and get the most out of your filter, READ TH IS M AN U AL CAREFU LLY! The H igh Rate Sand Filter System: • Is designed to circulate and filter water in above ground swimming pools. •...
• BE SURE all air is out of system before testing. cause minor personal injury or property damage if ig- • Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-cm) nored. torque for testing.
TABLE I - O U TLIN E D IM EN SIO N S IN IN CH ES (mm) Filter M odel 24 (610) 30-7/8 (784) 15-3/4 (400) 21-11/16 (551) 26-1/16 (662) 15”(406mm) Filters 26-9/16 (675) 33-5/16 (846) 17-3/4 (451) 24-1/4 (616) 27-1/16 (692) 17”(457mm) Filters 20”...
GENERAL INFORMATION Piping: • Use teflon tape or Plasto-J oint Stik on all male con- • Clean a new pool as well as possible before filling nections of plastic pipe and fittings except unions. D O pool and operating filter. Excess dirt and large particles of foreign matter in the system can cause serious dam- N O T use pipe compounds on plastic pipe;...
“ PUMP” should point toward pump. Filter Setup 4. Tighten clamp knob until clamp ends (under bolt) are Assembly: See Figures 2 through 5 for filter assembly. 1/4” (6mm) apart. Tap around outside of clamp with a mallet to help seat clamp. Loading Sand M edia H azardous pressure.
8. System is ready for startup. ELECTRICAL N O TICE: If there are leaks from beneath valve/clamp Risk of electrical shock. area, STOP PUMP , release all pressure, remove clamp Plug pump into a and valve and clean sealing surfaces. grounded, GFCI-protected 115 Follow directions under “...
Valve Setting Valve Setting Purpose/Flow Purpose/Flow Valve Setting Purpose/Flow BACKWASH FILTER WASTE Reverses flow for Normal filtration and Lowers pool level or cleaning; water vacuuming; water goes drains pool; water goes through filter through filter to pool. bypasses filter, to waste. goes to waste.
2. To vacuum, insert hose into skimmer suction manifold deterioration over the shutdown period. Have a quali- or into vacuum line in pool wall. See instructions pro- fied serviceman repair/replace wiring as needed. vided by pool builder or pool manufacturer. Start Inspect and tighten all watertight connections.
M U LTI-PO RT VALVE SERVICE Valve Removal H azardous pressure. Stop pump and re- H azardous pressure. Stop pump and re- lease all pressure from system before working on filter, lease all pressure from system before working on filter, valve, or clamp.
PUMP SERVICE Pump Assembly: 1. Examine seal cup and O-Rings. Replace anything that To protect against possible electric shock, shows signs of wear or damage. use only identical replacement parts when servicing. 2. Check the shaft seal (Key No. 10, Page 15) for scor- System should only be serviced by qualified personnel.
TROUBLESHOOTING TROUBLESHOOTING GUIDE – PUMP GUIDE – FILTER Read and understand safety and operating instruc- A. Short Cycle between backwashes: tions in this manual before doing any work on N O TICE: Time between backwashes will vary with each pump. installation and between different areas of the country.
Page 13
1277 0994 Repair Parts List - Filter M O D ELS J SAL20D -06 J SAL17D -06 J SAL20E-06 J SAL15D -06 J SAL17E-06 J SAL20E-09 N o. J SAL15E-06 J SAL17E-09 J SAL20F-06 N o. Part D escription U sed 15”...
REPAIR PARTS LIST POOL PUM PS 3/ 4 thru 1-1/ 2 HP Single Speed 1 Hp Dual Speed N O TICE: AT23 series models use the same front plate and seal plate as other models; however, they are rotated 90 ° counter-clockwise when installed.
Page 15
REPAIR PARTS LIST W C112-148 M ULTIPORT VALVE A q u a t o o l s .WATERFORD, WI. 53185 Part N o. D escription Q ty. N umber Decal, Valve Handle 32145-4016 Handle 14962-0032 Dowel Pin 35857-0021 Washer 14965-0007 Decal, Operating Instr.
3rd year 80% covered, etc.). one (1) year from date of installation. The foregoing warranties relate to the original consumer pur- chaser (“Purchaser”) only. Sta-Rite shall have the option to re- Year from date Product specific warranties: pair or replace the defective product, at its sole discre- of installation tion.