SATO CL408e Service Manual page 169

Hide thumbs Also See for CL408e:
Table of Contents

Advertisement

Label Dispenser Installation
FRONT DOOR
STEP
16.
17.
18.
19.
20.
PN 9001078
Rev. A
LABEL DISPENSER
MAGNETIC DOOR
LATCH
PINS 1 & 2 MUST BE IN UP
POSITION
PROCEDURE
To activate the Dispenser Senser, DSW3 pin 1 & 2 must be in the
upward position. .ig. 9-29 See chart on front panel of printer.
Close the Print Head, reinstall the LH Cover, close the RH Cover
and the .ront Door. .igs. 9-10, 9-11, & 9-28
Power up the printer and verify that all gears, belts, and drive
assemblies are functional. If necessary, adjust the sensitivity level
of the Label Taken Sensor and the position of the dispensing plate.
Adjustment of the Label Taken Sensor level is made by turning the
potentiometer located next to the connector slot until the green
LED illuminates with no blockage to the sensor. The green LED
should not be lit when the Label material is blocking it. .or
complete adjustment procedures refer to D-6 in the Operators
Manual. .ig. 9-29
Run several labels and adjust the pitch offset so that the label
material backfeeds correctly. Return the printer to service.
SATO CL408e/CL412e Service Manual
Section 9. Optional Accessories
PRINT
HEAD
LATCH
LATCH
TURN POTENTIOMETER TO
ADJUST LABEL TAKEN
Fig. 9-28
Fig. 9-29
SENSOR
Page 9-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl412e

Table of Contents