Label Dispenser Installation
STEP
PROCEDURE
3.
Remove (4) screws holding the Backing Take Up Spindle Assembly Access
Plate (inside mechanical section). Retain the screws from the Access Plate
for installing the Backing Take Up Spindle Assembly. .ig. 9-12
4.
Install the Backing Take Up Spindle Assembly by guiding the drive belt
through the open access cavity and then gently sliding the drive gear
portion through the access opening. Orient the unit so that the bracket legs,
which attach to the plate, are to the top and to the right. The belt will exit
from the bracket on the left side. Secure the Backing Take Up Spindle
Assembly with the (4) screws that were removed in STEP 3. .ig. 9-13
5.
Check the tension of the timing drive belt before loosening the motor. The
timing belt must be restored to it’s original tension after the Spindle
Assembly is installed.
6.
Loosen the four screws that hold the stepper motor in place and slide the
motor up in the motor mounting bracket. Remove the main timing belt
from the motor drive shaft and then install the Backing Take Up Spindle
Assembly timing drive belt on the inside track of the motor shaft. Reinstall
the motor for optimum tension on both belts. Tighten the four screws that
hold the motor in place. .igs. 9-14 & 9-15
Page 9-8
RAISE RH
COVER
LOOSEN (2) INSIDE
SCREWS HOLDING LH
Figs. 9-11
SECURING COVER TO THE
SATO CL408e/CL412e Service Manual
COVER
LH COVER
REMOVE (2) SCREWS
BASE
PN 9001078
Rev. A