Mitsubishi Electric PLA-RP-BA Technical Data Manual page 59

Mitsubishi electric split-type, heat pump air conditioners
Hide thumbs Also See for PLA-RP-BA:
Table of Contents

Advertisement

PEAD-RP60GA
PEAD-RP71GA
[LEGEND]
SYMBOL
NAME
I.B.
INDOOR CONTROLLER BOARD
FUSE
FUSE(T6.3AL250V)
ZNR
VARISTOR
CN2L
CONNECTOR(LOSSNAY)
CN24 CONNECTOR(HEATER)
CN32
CONNECTOR(REMOTE SWITCH)
CN41
CONNECTOR(HA TERMINAL-A)
CN51 CONNECTOR(CENTRALLY CONTROL)
CN90
CONNECTOR(WIRELESS)
LED1 POWER SUPPLY(I.B.)
LED2
POWER SUPPLY(REMOTE CONTROLLER)
LED3
TRANSMISSION(INDOOR·OUTDOOR)
B
L
U
CN22
(BLU)
LED1
LED2
LED3
WHT
2
BLK
1
B
TB5
L
TO MA-REMOTE
B
2
U
L
CONTROLLER
1
U
DC8.7-13V
TB4
S3
BRN
ORN
S2
S1
YLW
TO OUTDOOR UNIT
<wA>
(IN CASE OF CONNECT
THE REPLACEMENT WIRING)
L
N
1 2
S1
1
2
S2
1 2
S3
TO CND
TO CN3C
Notes:
1. SymboIs used in wiring diagram above are,
2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings.
3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing.
4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system of
power and signal.
w1: When supplying power separately to indoor and outdoor units, refer to wA.
w2: For power supply system of this unit, refer to the caution label located near this diagram.
PEAD-RP100GA
SYMBOL
SWITCH(MODEL SELECTION)
SW1
SW2
SWITCH(CAPACITY CORD)
SWE
SWITCH(EMERGENCY OPERATION)
X1
RELAY(DRAIN PUMP)
RELAY(FAN MOTOR)
X4
X5
RELAY(FAN MOTOR)
X6
RELAY(FAN MOTOR)
P.B.
INDOOR POWER BOARD
C
CAPACITOR(FAN MOTOR)
MF
FAN MOTOR
TB4
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
INSIDE SECTION OF CONTROL BOX
TH1
TH2
TH5
B
L
U
1 2
1
1 2
1 2
2
1 2 3
1 2 3 4 5 6 7 8 9
CN20
CN21
CN29
CN31
(WHT)
(RED)
(WHT)
(BLK)
1
2
CN2L
(RED)
CN2D
(WHT)
ZNR
(BLU)
FUSE
CN3C
(ORN)
(RED)
CND
CNDK
3
1
W
3
B
1
O
3
Y
1
O
B
H
L
R
R
R
L
T
K
N
N
N
W
W
B
W
B
H
L
H
L
P.B.
T
K
T
K
2 1
3
1
CN2S
CNSK
(RED)
(WHT)
wA
2
1
SW1
MODELS
Model selection
switch
POWER SUPPLY
~(1PHASE)
60GA
230V 50Hz
1
2
3
4
5
71GA
TO OUTDOOR
UNIT
100GA
: Connector,
NAME
SYMBOL
TB5
TH1
TH2
TH5
1 2
1
2
3
4
1
2
CN51
CN41
CN24
CN90
(YLW)
(WHT)
(WHT)
(WHT)
X1
X1
(BLU)
CNP
3
1
SW2
Capacity cord
switch
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
ON
OFF
OFF
1 2 3 4 5
ON
OFF
: Terminal (block).
59
NAME
TERMINAL BLOCK(REMOTE CONTROLLER)
INTAKE AIR TEMP.THERMISTOR
(0: /15t, 25:/5.4t DETECT)
PIPE TEMP. THERMISTOR/LIQUID
(0: /15t, 25:/5.4t DETECT)
COND./EVA. TEMP. THERMISTOR
(0: /15t, 25:/5.4t DETECT)
I.B.
1
2
3
4
5
3
CN32
(WHT)
SW1
SW2
SWE
ON
OFF
X4
X5
X6
X5
X4
X6
7
5
3
1
(WHT)
FAN
G
Y
Y
B
R
L
L
L
Y
W
W
K
*External static pressure
*
CONNECTOR COLOR
220V
B
B
O
L
L
R
U
K
G
BLU
5Pa
1
2
3
4
5
6
(WHT)
WHT
35Pa
(Initial setting)
RED
50Pa
MF
C
230V
240V
10Pa
20Pa
50Pa
60Pa
70Pa
75Pa