Model name
Indoor unit
Outdoor unit
Cooling
Capacity
Total input
EER
Energy label class
SHF
Heating
Capacity
Total input
COP
Energy label class
Booster heater
Power supply
Phase
Cycle
Voltage
Breaker size
Indoor unit
Air flow
(Low-Medium2-Medium1-High)
External pressure
Sound level
(Low-Medium2-Medium1-High)
External finish (Panel)
Dimension
Unit (Panel)
Weight
Unit (Panel)
Field drain pipe O.D.
Outdoor unit
Air flow
Sound level at cooling
Sound level at heating
External finish
Dimension
Weight
Refrigerant pipe size
Gas side O.D.
Liquid side O.D.
Height difference
Refrigerant pipe length
Length
NOTE:
1. Rating conditions (ISO T1)
Cooling
Indoor : D.B. 27: (80˚F) W.B. 19: (66˚F)
Heating
Indoor : D.B. 20: (68˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46˚C
Cooling
Lower limit D.B. 19˚C, W.B. 15˚C
Upper limit D.B. 28˚C
Heating
Lower limit D.B. 17˚C
Btu/h
kW
kW
Btu/h
kW
kW
kW
[
Hz
V
A
CMM
CFM
Pa
dB(A)
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
mm
inch
CMM
CFM
dB(A)
dB(A)
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
kg
lbs
mm
inch
mm
inch
m
m
Outdoor : D.B. 35: (95˚F) W.B. 24: (75˚F)
Outdoor : D.B. 7: (45˚F)
Indoor
Outdoor
D.B. -5˚C
D.B. 21˚C, W.B. 15˚C
D.B. -11˚C, W.B. -12˚C
5
PLA-RP71BA2
PLA-RP100BA2
PUHZ-RP71VHA3
PUHZ-RP100VHA3
24,200
7.1(3.3-8.1)
10.0(4.9-11.4)
1.94
3.66
A
0.73
27,300
8.0(3.5-10.2)
11.2(4.5-14.0)
1.90
4.21
A
25
14-16-18-21
20-23-26-30
495-565-635-740
710-810-920-1060
0
28-30-32-34
32-34-37-40
White Munsell 6.4Y 8.9/0.4
258 (35)
33-1/16 (37-3/8)
33-1/16 (37-3/8)
10-3/16 (1-3/8)
23(6)
51(13)
55
1,940
47
48
Ivory Munsell 3Y 7.8/1.1
943
13 + 1-3/16
37-1/8
68
150
Max. 50
W.B. 6: (43˚F)
3. Guaranteed voltage
198~264V, 50Hz
4. Above data are based on the indicated voltage.
Indoor unit
Single phase 230V 50Hz
w
Outdoor unit
Single phase 230V 50Hz
w
If optional air protect guide installed. D.B.-15:
PLA-RP125BA2
PUHZ-RP125VHA2
34,100
42,700
12.5(5.5-14.0)
2.44
3.73
4.10
3.35
A
A
0.74
0.71
38,200
47,800
14.0(5.0-16.0)
2.54
3.51
4.41
3.99
A
A
1
50
230
32
22-25-28-31
780-880-990-1090
0
0
34-36-39-41
840 (950)
840 (950)
298 (35)
11-3/4 (1-3/8)
27(6)
60(13)
32
1-1/4
100
3,530
49
50
51
52
950
330+30
1,350
37-3/8
53-1/8
116
256
15.88
5/8
9.52
3/8
Max. 30
Max. 75