♦ If there has a path between any two end-stations,
containing five segments and four repeaters, then
at least two of the cable segments must be point-to-
point link segments (e.g., 10BASE-T or 10BASE-FL).
While the remaining segments may be populated
segments (that is, they can be 10BASE-2 or 10BASE-
5 segments with end nodes attached).
Fast Ethernet (100Mbps) networks have the following
connectivity rules:
♦ The maximum length of a twisted-pair segment (that
is, the distance between a port on the hub and an
addressable network device such as an end-station
computer, server, or Fast Ethernet switch) is 100
meters. All cabling should be certified as Category 5
or higher UTP or equivalent (for example, Type 1
STP with RJ-45 plugs).
♦ The maximum diameter of a collision domain is 205
meters using two Class II hubs uplinked together.
♦ Between any two end-stations in a collision domain,
there may be up to three cable segments and two
Class II hubs.

Hub-to-end-node Connections

After the hub is properly installed, it can support up to five
end-node connections.
Each Fast Ethernet connection requires either a Category
5 UTP cable or a Type 1 STP cable. These cables can be up
to 100 meters long.
Each Ethernet connection requires a Category 3 or better
UTP cable. It is recommended that you use Category 5
10
Making Connections