400v class compact inverter
Table of Contents

Advertisement

2nd voltage/
frequency
characteristics
Torque boost
2nd torque boost
level
Accel./Decel. time
Accel./Decel.
characteristics
2nd accel./Decel.
time
Multi-speed
frequency setting
Skip frequency
setting
Upper frequency
setting
Lower frequency
setting
Bias/gain frequency
settings
External stop
function
Regenerative
braking torque
DC braking
Analog output
Open collector
output
85
Optional base frequency setting for 45 to 250Hz
Optional setting for 0 to 40%
Optional setting for 0 to 40%
0.04 to 999 sec. (individual accel. and decel. time setting)
Linear
0.1 to 999 sec. (individual accel. and decel. time setting)
Up to 8 preset frequency settings (optional setting)
Up to 3 place settings
(skip frequency band setting from 1 to 10Hz)
Optional setting from 0.5 to 250Hz
Optional setting from 0.5 to 250Hz
Bias frequency : set from –99 to 250Hz
Gain frequency : set from 0 to 250Hz
Select from auxiliary stop or coast-to-stop (selection setting)
20% or more
100% or more when brake resistor (option) is connected.
Operates when less than stop frequency
Braking torque level : 0 to 100 (set between 20 levels)
Braking time
: Optional setting for 0.1 to 120 seconds
Output specifications : 0 to 5V (max. 1mA)
Output functions
: Output frequency, output current proportional
Output specifications : Max. rating 50VDC, 50mA
Output functions
: Run signal, arrival signal, overload prealarm,
(selection changeover)
frequency detection, reverse run signal, fault
warning, output frequency/current proportional
PWM signal (cycle 1ms)