Panasonic VF0 Series 400V class Instruction Manual page 54

400v class compact inverter
Table of Contents

Advertisement

POWER LOSS START MODE (Parameter P48)
CAUTION
Depending on the start mode function setting, if the run signal is ON and the power is turned
ON or the power is restored after a power failure, the unit may start (restart) suddenly.
(Design the machine so that personal safety can be ensured even if the unit starts suddenly.)
Failure to do so could lead to injury.
Depending on the start mode function setting, if the fault trip is reset with the run signal
present, the unit may restart suddenly.
(Reset the trip after ensuring personal safety.)
Failure to do so could lead to injury.
This parameter sets the starting operation for when an externally set run signal is input when
the power is turned ON.
∗ The factory setting is "1" (OP stop).
∗ When set to "0" : Operation starts immediately when the power is turned ON.
∗ When set to "2" : Operation starts after the wait time has elapsed after the power is
Data setting
value
0
1
2
3
53
:
turned ON.
Outline
operation
Operation starts immediately when the power is turned ON and the low
Run
voltage level (LU level) is exceeded.
The inverter OP trips when the power is turned ON and the low voltage
level (LU level) is exceeded.
"OP" stop
Turn the start input signal OFF once, reset the inverter and then turn the
run signal ON again to resume operation.
The inverter starts when the power is turned ON, the low voltage level
Operate after
(LU level) is exceeded and the wait time is passed.
wait time
(The wait time is set with parameter P50.)
The inverter OP trips when the power is turned ON and the low voltage
level (LU level) is exceeded.
Turn the run signal OFF once, reset the inverter and then turn the run
"OP" stop
signal ON again to resume operation.
(This setting will function in the same manner as data "1" if the run
signal is ON when the power is turned ON. However, starting after the
wait time has elapsed is possible during normal startup.)
Details of operation

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf0 series

Table of Contents