SKY
7.10.2 Wiring the Outdoor Unit
P LUG TO CONNE CT
W ITH OUTDOOR
S E NS OR CABLE (Th3)
• Remove the outdoor unit side cover.
• Connect the wires to the terminal block male-female, in accordance with the color coding,
as shown in Fig. 7-11.
• Connect the outdoor sensor cable, making sure the connector is properly inserted.
• Secure the inter-unit electrical cable to the outdoor unit using the clamp.
• Make sure that all screws and wires are properly fastened. Loose wires or connections can
cause damage and present a fire hazard!
• Reassemble the side cover.
7.11 Finishing the Job
• Hide the tubing wherever possible.
• Make sure that the drainage tube slopes downstream along its entire length.
• Insulate tubing connections with the insulation materials supplied.
• Fasten tubes to the outside wall.
• Seal the hole through which the cables and tubing are passing.
• Connect the air conditioner to the power source. Check all air conditioning operating
modes. Consult the user manual.
INTE R - UNIT
E LE CTRICAL CABLE
Fig. 7-13
-
34
-
CLAMP
Need help?
Do you have a question about the ANL-100 and is the answer not in the manual?
Questions and answers