E2: T9 Temperature Set Point; E8: Anti-Legionella Function; E13: Floor Heating Temperature - Nibe MT-WH 2029-F User Manual

Domestic hot water heat pump
Hide thumbs Also See for MT-WH 2029-F:
Table of Contents

Advertisement

E2: T9 temperature set point

Here a temperature can be set which can be used in connection with menu item E19 and tem-
perature sensor T9. This is a separate sensor, which is not part of standard delivery.
See E19=2, 4 or 5 for further description.
Options: 0-30°C
Factory setting: 21°C

E8: Anti-legionella function

If the value is set to 1, the water will be heated to 65°C with the help of the electrical immersion
heater once a week to disinfect the water tank. If the value is set to 0, the disinfection function
is turned off.
Options: 0-1
Factory setting: 0
E9: Operating in cold surroundings ON/OFF
Value of 0: If the inlet air temperature (T5) is colder than the value set at menu point E10, the
compressor will stop and the electrical immersion heater activated automatically when required
(P5 and temperature sensor T7). The compressor can start again if the intake air temperature
(T5) has been higher than the temperature set at menu point E10 for 30 minutes.
Value of 1: If the inlet air temperature (T5) is colder than the value set at menu point E10, the
compressor will not stop, but the electrical immersion heater is activated automatically when
required (P5 and temperature sensor T7).
Options: 0-1
Factory setting: 0
E10: Operating in cold surroundings temperature
Here the temperature is set determining when the compressor is disengaged or when the im-
mersion heater is engaged. See menu item E9.
Options: -5-10 °C
Factory setting: 0 °C

E13: Floor heating temperature

Here a temperature is set, which can be used in connection with menu item E19=2, i.e., the
minimum temperature, at which the circulation pump for the floor heating starts. If the tempera-
ture T8 (water tank, bottom) is less than the value set at menu point E13, the circulation pump
stops.
Options: 20-50 °C
Factory setting: 35 °C
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mt-wh 2029-1fs

Table of Contents