W I R I N G
Important:
Wiring at 7 and 12 will be recognized as an Open Only
command, and Will Not close the gate. To Close the
gate with this wiring configuration, the control board
timer must be turned ON. If the timer is not turned on,
the gate will remain open. To provide close command
use 4 and 5.
Wiring at 4 and 5 will be recognized as a
Three Push Button command. The First
command will open the gate. The
Second command will
stop the gate. The Third
command will close the
gate.
Pin 7 and 12 for Open Only command
Card Reader
Digital Lock
Elite Entry Phone
1 (24V) / Ground
2 (Relay)
3 (Radio Power) / +24V
A D D I T I O N A L
Exit Loop
Detector
Mount receiver inside the control board
box as shown using velcro. Note that the
receiver is mounted upside down so the
antenna can fit through the hole at the
bottom of the control board box.
J3 Plug
Connector
18
I N P U T S
J3 Plug
J3 Plug
Connector
Input for 3 push button control
Key Switch
Push Button
Card Reader
black
white
red
Control Board
Digital Lock

Hide quick links: