P R O C E D U R E
A d j u s t i n g
Step 11:
Adjust the travel distance of the gate with the limit switches. Loosen the 2 bolts of each limit switch
armature. Slide to adjust. Position the outside limit switches of each armature to stop the gate in the "full open"
and "full closed" positions. Re-tighten armature bolts when gate positions are correct.
Limit Switch
Armature
Adjustment Bolts
F O R
t h e
L i m i t
Outside Limit
Switch
Inside Limit
Switch
Adjustment Bolts
Step 12:
Reinstall the operator cover with the 4 screws to complete
the installation.
12
I N S T A L L A T I O N
S w i t c h e s
Inside Limit Switch
Limit Switch Armature
Outside Limit Switch