Hcit Slide Assembly With Spring Removal - Lexmark X734de Service Manual

Mfp
Hide thumbs Also See for X734de:
Table of Contents

Advertisement

7526

HCIT slide assembly with spring removal

1.
Remove the HCIT controller board assembly. See
page
4-256.
2.
Disconnect the two springs (A) from the frame.
Note: Leave the springs attached to the cam size sensing plate (B) and the actuator switch.
3.
Slide the cam size sensing plate (B) through the access hole in the rear side frame.
4.
Remove the media size actuator from the card mount option (C).
5.
Snap loose the actuator switch (D), and remove.